Development and validation of a new stability indicating RP-UFLC method for the quantification of Molnupiravir

Molnupiravir is an anti-viral medication. A new stability indicating RP-UFLC method was proposed for the estimation of Molnupiravir in capsules. Shimadzu Model CBM-20A/20 Alite UFLC system with PDA detector and Zorbox C18 column were used for the chromatographic study. Mobile phase mixture consisting of 0.1% Acetic acid: Acetonitrile (35:65, v/v) with a flow rate 0.8 ml/min was chosen for the chromatographic elution of Molnupiravir (Detection wavelength 245 nm). The method was linear over the concentration range 2.0-100 mg/ml with linear regression equation, y = 29137x + 3455.8 (R² = 0.9999). The LOD and LOQ were found to be 0.4574 mg/ml and 1.548 mg/ml respectively. Forced degradation studies were performed and the method was validated as per ICH guidelines.

Authors

Institutions

Publication Details

Journal
Research Journal of Pharmacy and Technology
Published
2025-04-12
DOI
https://doi.org/10.52711/0974-360x.2025.00241
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of a new stability indicating RP-UFLC method for the quantification of Molnupiravir

Asia Asia, Revu Baby Nalanda
Research Journal of Pharmacy and Technology
Antibiotics Pharmacokinetics and Efficacy
article

Development and validation of a new stability indicating RP-UFLC method for the quantification of Molnupiravir

Asia Asia, Revu Baby Nalanda
article en

Abstract

Molnupiravir is an anti-viral medication. A new stability indicating RP-UFLC method was proposed for the estimation of Molnupiravir in capsules. Shimadzu Model CBM-20A/20 Alite UFLC system with PDA detector and Zorbox C18 column were used for the chromatographic study. Mobile phase mixture consisting of 0.1% Acetic acid: Acetonitrile (35:65, v/v) with a flow rate 0.8 ml/min was chosen for the chromatographic elution of Molnupiravir (Detection wavelength 245 nm). The method was linear over the concentration range 2.0-100 mg/ml with linear regression equation, y = 29137x + 3455.8 (R² = 0.9999). The LOD and LOQ were found to be 0.4574 mg/ml and 1.548 mg/ml respectively. Forced degradation studies were performed and the method was validated as per ICH guidelines.

Research Journal of Pharmacy and Technology
GITAM University (IN)
Openalex Percentile: Top 88%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.