A Comparison of Ultra-Widefield Imaging Quality Obtained with Zeiss Clarus and Optos for Virtual Medical Retina Services

<b>Background:</b> Virtual clinics (VCs) have proven to be an effective solution for the increasing strain on Medical Retina (MR) services, although imaging quality issues (IQIs) persist. Our aim was to compare the quality of two ultra-wide-field (UWF) imaging modalities (Optos and Clarus) in real-world MR-VC settings. <b>Methods:</b> We conducted a real-world, prospective study. Data were collected from 6 Moorfields NHS Trust MR-VCs between September and October 2024. We obtained patient demographics and characteristics, primary diagnosis, UWF imaging types and images obtained, and follow-up outcomes. <b>Results:</b> Optos (California RG/RGB, and Monaco) was used for 56.7% (<i>n</i> = 152) and Zeiss Clarus 500 for 43.3% (<i>n</i> = 116) of the total cohort (<i>n</i> = 268). No statistically significant difference (<i>p</i> = 0.14) was found between the two in terms of the rates of IQIs. FAF (<i>p</i> = 0.001) acquisition was significantly higher when Optos was used. Of the patients affected by IQIs, 10 were examined in a face-to-face clinic (F2FC). No difference in IQI rates was observed when pathology-related poor image quality was considered (<i>p</i> = 0.561). A significantly (<i>p</i> = 0.001) higher rate of F2F follow-ups was found for red-flag pathologies and unexplained vision loss, with a statistically significantly higher rate of virtual follow-ups for non-red-flag pathologies (<i>p</i> = 0.001). <b>Conclusions:</b> A total of 7.5% of the clinical decisions were impacted by IQIs; 11.1% of F2FC follow-ups. Neither UWF imaging modality type was inferior in terms of IQI rates. FAF acquisition was higher with Optos, likely representing greater user-dependency for Clarus. The outcomes were not influenced by FAF acquisition, indicating that routine acquisition is not required in MR-VCs and instead should be obtained when clinically required.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-08
DOI
https://doi.org/10.3390/jcm14103270
Citations
1
Primary Topic
Retinal Diseases and Treatments
Type
article
Field-Weighted Citation Impact
1.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparison of Ultra-Widefield Imaging Quality Obtained with Zeiss Clarus and Optos for Virtual Medical Retina Services

Matthew Azzopardi, Ling Zhi Heng, Michail Katzakis, Georgios Koutsocheras et al.
1 citations
Journal of Clinical Medicine
Retinal Diseases and Treatments
1.71
article

A Comparison of Ultra-Widefield Imaging Quality Obtained with Zeiss Clarus and Optos for Virtual Medical Retina Services

Matthew Azzopardi, Ling Zhi Heng, Michail Katzakis, Georgios Koutsocheras, Abison Logeswaran, Yu Jeat Chong, Chrysanthi Tsika, Waheeda Rahman, Bahar Demir, Sneha Gridhar
article en
1 citations

Abstract

<b>Background:</b> Virtual clinics (VCs) have proven to be an effective solution for the increasing strain on Medical Retina (MR) services, although imaging quality issues (IQIs) persist. Our aim was to compare the quality of two ultra-wide-field (UWF) imaging modalities (Optos and Clarus) in real-world MR-VC settings. <b>Methods:</b> We conducted a real-world, prospective study. Data were collected from 6 Moorfields NHS Trust MR-VCs between September and October 2024. We obtained patient demographics and characteristics, primary diagnosis, UWF imaging types and images obtained, and follow-up outcomes. <b>Results:</b> Optos (California RG/RGB, and Monaco) was used for 56.7% (<i>n</i> = 152) and Zeiss Clarus 500 for 43.3% (<i>n</i> = 116) of the total cohort (<i>n</i> = 268). No statistically significant difference (<i>p</i> = 0.14) was found between the two in terms of the rates of IQIs. FAF (<i>p</i> = 0.001) acquisition was significantly higher when Optos was used. Of the patients affected by IQIs, 10 were examined in a face-to-face clinic (F2FC). No difference in IQI rates was observed when pathology-related poor image quality was considered (<i>p</i> = 0.561). A significantly (<i>p</i> = 0.001) higher rate of F2F follow-ups was found for red-flag pathologies and unexplained vision loss, with a statistically significantly higher rate of virtual follow-ups for non-red-flag pathologies (<i>p</i> = 0.001). <b>Conclusions:</b> A total of 7.5% of the clinical decisions were impacted by IQIs; 11.1% of F2FC follow-ups. Neither UWF imaging modality type was inferior in terms of IQI rates. FAF acquisition was higher with Optos, likely representing greater user-dependency for Clarus. The outcomes were not influenced by FAF acquisition, indicating that routine acquisition is not required in MR-VCs and instead should be obtained when clinically required.

Journal of Clinical MedicineVol. 14(10)
Moorfields Eye Hospital NHS Foundation Trust (GB), Birmingham and Midland Eye Centre (GB)
Moorfields Eye Hospital NHS Foundation Trust
No poverty
Openalex Percentile: Top 19%
Retinal Diseases and Treatments
1.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.