Biomimetic Polythiophene: g-C<sub>3</sub>N<sub>4</sub> Nanotube Composites with Induced Creatinine and Uric Acid Specificity for Portable CKD and Gout Detection

Despite significant advancements in disease diagnostics, the development of portable, highly selective, and low-cost electrochemical sensors for real-time, noninvasive detection of chronic kidney disease (CKD) and gout biomarkers remains a challenge. In this work, we demonstrate an inexpensive CKD and gout diagnostic platform with the incorporation of biomimetic polymer matrix nanocomposites based on creatinine (CRE) and uric acid (UA) imprinted conducting polythiophene (MIP) and graphitic carbon nitride nanotubes (NTs). These nanocomposites are termed CRE-MIPNT or UA-MIPNT, depending on the template. Disposable electrochemical devices are fabricated by anchoring CRE-MIPNT or UA-MIPNT nanocomposites on screen-printed Au microelectrodes. The surface micrographs exhibit the integration of NTs in the polymer matrix, resulting in highly leptokurtic surfaces. Consequently, the charge transfer resistance at the electrode-electrolyte interface is significantly reduced, as characterized by electrochemical impedance spectroscopy. An increase in the electroactive surface area and charge transfer kinetics is also observed for the CRE-MIPNT/Au-SPE and UA-MIPNT/Au-SPE sensors. In comparison to nonimprinted sensors, their performance is investigated in terms of their voltammetric response toward various biomarker concentrations in standard redox solutions. The sensitivity in the CV measurements is 0.59 μA cm<sup>-2</sup> nM<sup>-1</sup> for CRE-MIPNT/Au-SPE and 0.78 μA cm<sup>-2</sup> μM<sup>-1</sup> for UA-MIPNT/Au-SPE sensors, with detection limits of 390 pM and 162 nM for CRE and UA, respectively. The sensors demonstrate high selectivity toward the target analytes while showing minimal interference from other metabolites. Moreover, recovery rates for spiked saliva samples ranged between 97 and 102%, which indicates the reliability of the sensor for real-world applications.

Authors

Institutions

Publication Details

Journal
ACS Applied Bio Materials
Published
2025-05-08
DOI
https://doi.org/10.1021/acsabm.5c00371
Citations
6
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
4.38

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomimetic Polythiophene: g-C3N4 Nanotube Composites with Induced Creatinine and Uric Acid Specificity for Portable CKD and Gout Detection

Noor Shahzad, Zohaib Saddique, Adeel Afzal, Maleeha Saeed
6 citations
ACS Applied Bio Materials
Electrochemical sensors and biosensors
4.38
article

Biomimetic Polythiophene: g-C3N4 Nanotube Composites with Induced Creatinine and Uric Acid Specificity for Portable CKD and Gout Detection

Noor Shahzad, Zohaib Saddique, Adeel Afzal, Maleeha Saeed
article en
6 citations

Abstract

Despite significant advancements in disease diagnostics, the development of portable, highly selective, and low-cost electrochemical sensors for real-time, noninvasive detection of chronic kidney disease (CKD) and gout biomarkers remains a challenge. In this work, we demonstrate an inexpensive CKD and gout diagnostic platform with the incorporation of biomimetic polymer matrix nanocomposites based on creatinine (CRE) and uric acid (UA) imprinted conducting polythiophene (MIP) and graphitic carbon nitride nanotubes (NTs). These nanocomposites are termed CRE-MIPNT or UA-MIPNT, depending on the template. Disposable electrochemical devices are fabricated by anchoring CRE-MIPNT or UA-MIPNT nanocomposites on screen-printed Au microelectrodes. The surface micrographs exhibit the integration of NTs in the polymer matrix, resulting in highly leptokurtic surfaces. Consequently, the charge transfer resistance at the electrode-electrolyte interface is significantly reduced, as characterized by electrochemical impedance spectroscopy. An increase in the electroactive surface area and charge transfer kinetics is also observed for the CRE-MIPNT/Au-SPE and UA-MIPNT/Au-SPE sensors. In comparison to nonimprinted sensors, their performance is investigated in terms of their voltammetric response toward various biomarker concentrations in standard redox solutions. The sensitivity in the CV measurements is 0.59 μA cm<sup>-2</sup> nM<sup>-1</sup> for CRE-MIPNT/Au-SPE and 0.78 μA cm<sup>-2</sup> μM<sup>-1</sup> for UA-MIPNT/Au-SPE sensors, with detection limits of 390 pM and 162 nM for CRE and UA, respectively. The sensors demonstrate high selectivity toward the target analytes while showing minimal interference from other metabolites. Moreover, recovery rates for spiked saliva samples ranged between 97 and 102%, which indicates the reliability of the sensor for real-world applications.

ACS Applied Bio MaterialsVol. 8(5)
University of the Punjab (PK), Chinese Academy of Sciences (CN), Sensors (United States) (US), Changchun Institute of Applied Chemistry (CN)
University of Hafr Al Batin, Ministry of Education – Kingdom of Saudi Arabi
Zero hunger
Openalex Percentile: Top 6%
Electrochemical sensors and biosensors
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.