Calibration and Validation of Microscopic Simulation Model of Ambedkar Statue Junction Based on VISSIM

VISSIM has become one of the most useful and reliable programs utilized by contemporary engineers and researchers in the processes of evaluation of control operations and strategies of transportation. In this study calibration and validation techniques of VISSIM parameters that derive from the need to accurately match the simulations results of the models with the observed field data. Micro-simulation is a widely used and one of the most effective ways to predict traffic behavior of urban intersections. The advanced microscopic traffic simulator is PTV VISSIM. It has been used to evaluate the peak-hour traffic operating conditions to replicate the total scenario several local vehicles are modelled. The model was duly calibrated using field data and validated using Geoffrey E. Heavers (GEH) statistics comparisons or GEH values, FDistribution, T-distribution and Chi-squared test. A key component of simulation modeling is the calibration and validation stage of the model building process. Calibration is defined as the adjustment of computer simulation model parameters to accurately reflect prevailing conditions of the roadway network. Validation is defined as the process of comparing simulated model results with field measurements in order to determine the accuracy of the simulation model. In a metropolitan city of a developing country, for instance Ambedkar Statue Junction model has been calibrated from the actual field data and using the outcome the total speed and volume for an intersection of that corridor was estimated.

Authors

Institutions

Publication Details

Journal
International Journal for Research in Applied Science and Engineering Technology
Published
2025-05-08
DOI
https://doi.org/10.22214/ijraset.2025.70383
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration and Validation of Microscopic Simulation Model of Ambedkar Statue Junction Based on VISSIM

Mrs. Soniya Grace
International Journal for Research in Applied Science and Engineering Technology
Medical Imaging and Analysis
article

Calibration and Validation of Microscopic Simulation Model of Ambedkar Statue Junction Based on VISSIM

Mrs. Soniya Grace
article en

Abstract

VISSIM has become one of the most useful and reliable programs utilized by contemporary engineers and researchers in the processes of evaluation of control operations and strategies of transportation. In this study calibration and validation techniques of VISSIM parameters that derive from the need to accurately match the simulations results of the models with the observed field data. Micro-simulation is a widely used and one of the most effective ways to predict traffic behavior of urban intersections. The advanced microscopic traffic simulator is PTV VISSIM. It has been used to evaluate the peak-hour traffic operating conditions to replicate the total scenario several local vehicles are modelled. The model was duly calibrated using field data and validated using Geoffrey E. Heavers (GEH) statistics comparisons or GEH values, FDistribution, T-distribution and Chi-squared test. A key component of simulation modeling is the calibration and validation stage of the model building process. Calibration is defined as the adjustment of computer simulation model parameters to accurately reflect prevailing conditions of the roadway network. Validation is defined as the process of comparing simulated model results with field measurements in order to determine the accuracy of the simulation model. In a metropolitan city of a developing country, for instance Ambedkar Statue Junction model has been calibrated from the actual field data and using the outcome the total speed and volume for an intersection of that corridor was estimated.

International Journal for Research in Applied Science and Engineering TechnologyVol. 13(5)
Jawaharlal Nehru Technological University, Hyderabad (IN)
Openalex Percentile: Top 91%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.