New Rolling Circle Transcription Based on Allosteric Transcription Factors (aTFs) for Trace Detection of Water Contaminants

Antibiotic and heavy metal contamination in water poses a severe global public health risk, yet conventional detection methods remain constrained by reliance on complex laboratory instrumentation. Although cell-free biosensors utilizing allosteric transcription factors (aTFs) offer promising alternatives, their limited sensitivity impedes reliable detection of small-molecule contaminants. To address this limitation, we developed allosteric transcription factors (aTFs)-regulated rolling circle transcription assay (ARCTA) for ultrasensitive detection of water contaminants. The ARCTA system employs a circular DNA template comprising a double-stranded region with a T7 promoter and aTFs binding sequence, alongside a single-stranded domain transcribable into fluorescent RNA. Target-specific recognition by aTFs enables rapid, efficient transcription and amplification of fluorescent RNA, achieving an exceptionally low detection threshold. Applied to tetracycline, oxytetracycline, erythromycin, clarithromycin, Hg<sup>2+</sup>, Pb<sup>2+</sup>, Cd<sup>2+</sup>, and As<sup>3+</sup> in water samples, ARCTA demonstrated detection limits of 1.25 nM, 0.93 nM, 0.28 nM, 0.45 nM, 0.034 nM, 0.006 nM, 0.13 nM, and 0.016 nM, respectively, and all had a broad dynamic ranges.Notably, ARCTA by designing distinct circular DNA templates to transcribe wavelength-specific fluorescent RNAs, enabling the simultaneous detection of multiple targets. In addition, the system also exhibited robust performance in real-world applications, underscoring its practicality. These results highlight ARCTA's potential as a transformative tool for ultrasensitive monitoring of diverse small-molecule contaminants.

Authors

Publication Details

Journal
Analytical Chemistry
Published
2025-05-08
DOI
https://doi.org/10.1021/acs.analchem.5c00217
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New Rolling Circle Transcription Based on Allosteric Transcription Factors (aTFs) for Trace Detection of Water Contaminants

Huaixiu Bi, Zhiqiang Shen, Chao Li, Shang Wang et al.
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
article

New Rolling Circle Transcription Based on Allosteric Transcription Factors (aTFs) for Trace Detection of Water Contaminants

Huaixiu Bi, Zhiqiang Shen, Chao Li, Shang Wang, Chenyu Li, Bin Zhang, Xiaoli Zhang, Xiaobo Yang, Bin Xue, Yongkang Zhang, Zhigang Qiu, Chen Zhao, Jingfeng Wang, Ningkang Yu
article en

Abstract

Antibiotic and heavy metal contamination in water poses a severe global public health risk, yet conventional detection methods remain constrained by reliance on complex laboratory instrumentation. Although cell-free biosensors utilizing allosteric transcription factors (aTFs) offer promising alternatives, their limited sensitivity impedes reliable detection of small-molecule contaminants. To address this limitation, we developed allosteric transcription factors (aTFs)-regulated rolling circle transcription assay (ARCTA) for ultrasensitive detection of water contaminants. The ARCTA system employs a circular DNA template comprising a double-stranded region with a T7 promoter and aTFs binding sequence, alongside a single-stranded domain transcribable into fluorescent RNA. Target-specific recognition by aTFs enables rapid, efficient transcription and amplification of fluorescent RNA, achieving an exceptionally low detection threshold. Applied to tetracycline, oxytetracycline, erythromycin, clarithromycin, Hg<sup>2+</sup>, Pb<sup>2+</sup>, Cd<sup>2+</sup>, and As<sup>3+</sup> in water samples, ARCTA demonstrated detection limits of 1.25 nM, 0.93 nM, 0.28 nM, 0.45 nM, 0.034 nM, 0.006 nM, 0.13 nM, and 0.016 nM, respectively, and all had a broad dynamic ranges.Notably, ARCTA by designing distinct circular DNA templates to transcribe wavelength-specific fluorescent RNAs, enabling the simultaneous detection of multiple targets. In addition, the system also exhibited robust performance in real-world applications, underscoring its practicality. These results highlight ARCTA's potential as a transformative tool for ultrasensitive monitoring of diverse small-molecule contaminants.

Analytical ChemistryVol. 97(19)
Clean water and sanitation
Openalex Percentile: Top 91%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.