Biomechanical Impact of Cementation Technique Variations on Femoral Stem Stability: An In Vitro Polyurethane Model Study

<b>Background/Objectives:</b> Achieving optimal primary stability in cemented total hip arthroplasty remains a critical factor influencing long-term implant success. Variability in cementation techniques can significantly affect biomechanical performance, yet consensus on best practices is lacking. This study investigates the influence of cementation parameters on femoral stem fixation. <b>Methods:</b> This in vitro comparative study evaluated four cementation techniques-Classic (line-to-line), Press-Fit (undersized reaming), Overreaming (oversized reaming), and Valgus Malpositioning (15° deviation). An experimental model using standardized Polyurethane (PU) bone surrogates was developed. Mechanical testing assessed axial deformation and ultimate load capacity to failure. <b>Results:</b> The Press-Fit technique demonstrated significantly greater deformation (17.10 ± 0.89 mm) but a reduced load capacity (6317.47 ± 518.34 N) compared to the Classic approach. Overreaming and Valgus techniques both showed reduced mechanical performance, with Overreaming yielding the lowest structural integrity. <b>Conclusions:</b> Cement mantle thickness emerged as the primary determinant of biomechanical stability, surpassing the impact of implant positioning. While increased mantle thickness improves energy absorption, it may compromise ultimate strength. These findings underscore the importance of optimizing the cementation technique to balance flexibility and mechanical resistance, guiding surgical protocols toward improved implant longevity. This study introduces a novel integrative approach combining fluoroscopic assessment of cement mantle morphology with mechanical testing in a standardized model, providing new evidence on the relative influence of mantle thickness and implant malposition on femoral stem stability.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-08
DOI
https://doi.org/10.3390/jcm14103291
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Impact of Cementation Technique Variations on Femoral Stem Stability: An In Vitro Polyurethane Model Study

Diana Carina Iovanovici, Iosif Ilia, Csongor Toth, Liviu Gavrilă-Ardelean et al.
Journal of Clinical Medicine
Orthopaedic implants and arthroplasty
article

Biomechanical Impact of Cementation Technique Variations on Femoral Stem Stability: An In Vitro Polyurethane Model Study

Diana Carina Iovanovici, Iosif Ilia, Csongor Toth, Liviu Gavrilă-Ardelean, Laura Ioana Bondar, Caius Călin Miuţa, Dan Fruja, Brigitte Osser, Alexandru Pop, Roland Fazakas
article en

Abstract

<b>Background/Objectives:</b> Achieving optimal primary stability in cemented total hip arthroplasty remains a critical factor influencing long-term implant success. Variability in cementation techniques can significantly affect biomechanical performance, yet consensus on best practices is lacking. This study investigates the influence of cementation parameters on femoral stem fixation. <b>Methods:</b> This in vitro comparative study evaluated four cementation techniques-Classic (line-to-line), Press-Fit (undersized reaming), Overreaming (oversized reaming), and Valgus Malpositioning (15° deviation). An experimental model using standardized Polyurethane (PU) bone surrogates was developed. Mechanical testing assessed axial deformation and ultimate load capacity to failure. <b>Results:</b> The Press-Fit technique demonstrated significantly greater deformation (17.10 ± 0.89 mm) but a reduced load capacity (6317.47 ± 518.34 N) compared to the Classic approach. Overreaming and Valgus techniques both showed reduced mechanical performance, with Overreaming yielding the lowest structural integrity. <b>Conclusions:</b> Cement mantle thickness emerged as the primary determinant of biomechanical stability, surpassing the impact of implant positioning. While increased mantle thickness improves energy absorption, it may compromise ultimate strength. These findings underscore the importance of optimizing the cementation technique to balance flexibility and mechanical resistance, guiding surgical protocols toward improved implant longevity. This study introduces a novel integrative approach combining fluoroscopic assessment of cement mantle morphology with mechanical testing in a standardized model, providing new evidence on the relative influence of mantle thickness and implant malposition on femoral stem stability.

Journal of Clinical MedicineVol. 14(10)
University of Oradea (RO), Vasile Goldis Western University of Arad (RO), Institute e-Austria Timisoara (RO), Aurel Vlaicu University of Arad (RO)
Affordable and clean energy
Openalex Percentile: Top 83%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.