Indoor air quality in swiss primary schools: impacts of mechanical ventilation and seasonal variation
• Low CO₂, PM 2.5 & VOC concentrations in Swiss primary school classrooms • Mechanical ventilation further reducing CO 2 and TVOC levels by 20–30% • Acetaldehyde, formaldehyde, acetone, and ethanol ubiquitously found in classrooms • Lowest pollutant levels during summer regardless of ventilation type • COVID-19 protocols and energy shortages altering air quality profiles in winter Indoor air quality (IAQ) in classrooms significantly impacts the comfort, health, and cognitive performance of students and teachers. The COVID-19 pandemic heightened awareness of IAQ, leading to increasing adoption of mechanical ventilation systems in schools. This study investigates IAQ across 24 primary schools (11 equipped with mechanical ventilation) in the French-speaking region of Switzerland. Concentrations of carbon dioxide (CO 2 ), particulate matter (PM), and volatile organic compounds (VOCs) were monitored during four week-long campaigns spanning from autumn 2021 to winter 2023, partially encompassing the COVID-19 pandemic until February 2022 and heating energy shortages in winter 2023. Supplementary measurements of radon and nanoparticles were performed at selected locations. During school hours, the median concentrations of CO 2 and PM 2.5 were 560 ppm and 4 µg/m 3 , respectively (interquartile ranges: 450-780 ppm and 2-6 µg/m 3 , respectively). Total VOCs (TVOCs) concentrations averaged 41 ± 66 ppb (mean ± standard deviation; integrated measurement including nighttime and weekends). In autumn and winter, classrooms with mechanical ventilation had 20-30% lower CO 2 and TVOC levels compared to naturally ventilated ones. Notably, naturally ventilated classrooms had significantly higher TVOC but lower CO 2 levels in winter 2022 than in winter 2023, presumably due to more frequent window opening and cleaning practices tied to COVID-19 regulations. Commonly identified VOCs included acetaldehyde, formaldehyde, acetone, and ethanol. The findings underscore the effectiveness of mechanical ventilation in improving IAQ in schools, while highlighting the influence of seasonal and contextual factors on pollutant levels.
Authors
- Guillaume Suárez (ORCID: https://orcid.org/0000-0002-5914-1559)
- Matteo Cesari (ORCID: https://orcid.org/0000-0002-0348-3664)
- Vincent Perret (ORCID: https://orcid.org/0000-0002-7242-4828)
- Bowen Du (ORCID: https://orcid.org/0000-0001-5561-4390)
- Dusan Licina (ORCID: https://orcid.org/0000-0001-5945-0872)
- Corinne Hager Jörin (ORCID: https://orcid.org/0000-0001-9114-1092)
- Philippe Favreau
- Claude-Alain Roulet
- J. F. Rey (ORCID: https://orcid.org/0000-0003-2109-7641)
- Joëlle Goyette Pernot (ORCID: https://orcid.org/0000-0003-4699-0196)
Institutions
- Institution Genevoise de Maintien à Domicile (CH)
- Department of the Environment (GB)
- HES-SO Fribourg (CH)
- Centre universitaire de médecine générale et santé publique, Lausanne (CH)
- École Polytechnique Fédérale de Lausanne (CH)
- University of Lausanne (CH)
Publication Details
- Journal
- Building and Environment
- Published
- 2025-05-08
- DOI
- https://doi.org/10.1016/j.buildenv.2025.113146
- Citations
- 4
- Primary Topic
- Indoor Air Quality and Microbial Exposure
- Type
- article
- Field-Weighted Citation Impact
- 4.80
Funders
- U.S. Department of Energy
- École Polytechnique Fédérale de Lausanne
- Bundesamt für Gesundheit