Development of a Novel Proton Range Detector Using a Scintillator Disk Integrated With Copper Indium Gallium Selenide Solar Cells

Range errors in proton therapy can pose critical problems due to the steep dose gradient. Previously proposed range detectors using photomultiplier tubes and optical fibers have several limitations including use of external high-voltage sources, vulnerability to external forces, and complex signal transmission, which can cause inaccuracies in range measurement. This study aims to develop and assess a novel proton range detector that utilizes a scintillator disk with copper indium gallium selenide (CIGS) solar cells to overcome these challenges. The detector, consisting of a plastic scintillator disk, CIGS solar cells, and a data acquisition module, measures voltage signals from the solar cells through radioluminescence generated by the scintillator. We evaluated the dosimetric characteristics of our detector, focusing on range accuracy, dose linearity, dose rate dependence, energy dependence, spot position dependence. The detector showed range discrepancies of less than 1 mm, excellent dose linearity, dose rate independence within 1%, and energy independence within ±3%. Additionally, the signals near the disks center were consistent within 4% error across various spot positions. These findings suggest that the proposed detector, with its simplified configuration, offers high measurement accuracy and could be a promising alternative to other detectors based on photomultiplier tubes and optical fibers.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2025-05-08
DOI
https://doi.org/10.1109/trpms.2025.3568131
Primary Topic
Advanced Semiconductor Detectors and Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Novel Proton Range Detector Using a Scintillator Disk Integrated With Copper Indium Gallium Selenide Solar Cells

Young Kyung Lim, Se Byeong Lee, Jaeman Son, Hak‐Soo Kim et al.
IEEE Transactions on Radiation and Plasma Medical Sciences
Advanced Semiconductor Detectors and Materials
article

Development of a Novel Proton Range Detector Using a Scintillator Disk Integrated With Copper Indium Gallium Selenide Solar Cells

Young Kyung Lim, Se Byeong Lee, Jaeman Son, Hak‐Soo Kim, Geon Oh, Chankyu Kim, Dongseok Shin, Dongho Shin, Jeong‐Eun Rah, Jonghwi Jeong
article en

Abstract

Range errors in proton therapy can pose critical problems due to the steep dose gradient. Previously proposed range detectors using photomultiplier tubes and optical fibers have several limitations including use of external high-voltage sources, vulnerability to external forces, and complex signal transmission, which can cause inaccuracies in range measurement. This study aims to develop and assess a novel proton range detector that utilizes a scintillator disk with copper indium gallium selenide (CIGS) solar cells to overcome these challenges. The detector, consisting of a plastic scintillator disk, CIGS solar cells, and a data acquisition module, measures voltage signals from the solar cells through radioluminescence generated by the scintillator. We evaluated the dosimetric characteristics of our detector, focusing on range accuracy, dose linearity, dose rate dependence, energy dependence, spot position dependence. The detector showed range discrepancies of less than 1 mm, excellent dose linearity, dose rate independence within 1%, and energy independence within ±3%. Additionally, the signals near the disks center were consistent within 4% error across various spot positions. These findings suggest that the proposed detector, with its simplified configuration, offers high measurement accuracy and could be a promising alternative to other detectors based on photomultiplier tubes and optical fibers.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 10(2)
Seoul National University Hospital (KR), National Cancer Center (KR), Myongji Hospital (KR)
National Research Foundation of Korea
Affordable and clean energy
Openalex Percentile: Top 92%
Advanced Semiconductor Detectors and Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.