An Innovative Ultrasound Research Platform Integrating an Open Scanner and a 3072-Element Dense Array

High-end 4-D ultrasound (US) imaging systems typically use probes based on 2-D arrays containing thousands of transducers. Application specific integrated circuits (ASICs), embedded in the probe, manage the numerous transducers, significantly reducing the number of channels needed for the associated scanner. Unfortunately, the closed architecture of these high-end systems prevents research activities, such as the experimental testing of new imaging methods. This article presents the development and application of a novel 4-D US imaging research platform that combines the ULA-OP 256 open scanner and the Adult 4-D Premium transesophageal probe, integrating a rectangular 3072-transducer array. The hardware, software, and firmware developments specifically made on the scanner are described. The functionality of the novel system is demonstrated by comparing simulated and experimental acoustic fields when transmitting focused wide beams (FWBs) and planar diverging waves (PDWs). The latter beams are exploited for high-frame-rate imaging, demonstrating the platform capable of reconstructing, in real time, up to over 800 frames/s over arbitrary planes. In vivo, bi-plane, B-mode images from the carotid artery of a healthy volunteer have been obtained together with dynamic multigate spectral Doppler (MSD) images. The novel platform uniquely integrates the benefits of a programmable open scanner with a high-density 2-D array. By enabling the real-time evaluation of innovative 4-D imaging and Doppler methods, it has the potential to significantly impact applications so far tested with 2-D probes containing a limited number of elements.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2025-05-08
DOI
https://doi.org/10.1109/tuffc.2025.3568197
Citations
1
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.95

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Innovative Ultrasound Research Platform Integrating an Open Scanner and a 3072-Element Dense Array

Alessandro Dallai, Enrico Boni, Piero Tortoli, Alessandro Ramalli et al.
1 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Engineering Applied Research
0.95
article

An Innovative Ultrasound Research Platform Integrating an Open Scanner and a 3072-Element Dense Array

Alessandro Dallai, Enrico Boni, Piero Tortoli, Alessandro Ramalli, Valentino Meacci, Marco Crocco, Lorenzo Castrignano
article en
1 citations

Abstract

High-end 4-D ultrasound (US) imaging systems typically use probes based on 2-D arrays containing thousands of transducers. Application specific integrated circuits (ASICs), embedded in the probe, manage the numerous transducers, significantly reducing the number of channels needed for the associated scanner. Unfortunately, the closed architecture of these high-end systems prevents research activities, such as the experimental testing of new imaging methods. This article presents the development and application of a novel 4-D US imaging research platform that combines the ULA-OP 256 open scanner and the Adult 4-D Premium transesophageal probe, integrating a rectangular 3072-transducer array. The hardware, software, and firmware developments specifically made on the scanner are described. The functionality of the novel system is demonstrated by comparing simulated and experimental acoustic fields when transmitting focused wide beams (FWBs) and planar diverging waves (PDWs). The latter beams are exploited for high-frame-rate imaging, demonstrating the platform capable of reconstructing, in real time, up to over 800 frames/s over arbitrary planes. In vivo, bi-plane, B-mode images from the carotid artery of a healthy volunteer have been obtained together with dynamic multigate spectral Doppler (MSD) images. The novel platform uniquely integrates the benefits of a programmable open scanner with a high-density 2-D array. By enabling the real-time evaluation of innovative 4-D imaging and Doppler methods, it has the potential to significantly impact applications so far tested with 2-D probes containing a limited number of elements.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 72(7)
Esaote (Italy) (IT), University of Florence (IT)
Ministero dell’Istruzione, dell’Università e della Ricerca, Ministero dello Sviluppo Economico
Industry, innovation and infrastructure
Openalex Percentile: Top 26%
Engineering Applied Research
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.