Modified QuEChERS for antiepileptic drugs detection in forensic toxicology

This study aims to concurrently assess the blood concentrations of antiepileptic drugs including phenobarbital, carbamazepine, primidone, phenytoin in post-mortem samples through the application modified QuEChERS extraction. The serum samples were extracted and then purified using magnesium sulfate, PSA, and C18 sorbents and subsequently analyzed using HPLC/UV. One influencing parameter on the extraction process was the pH of sample. Extraction recoveries were in the range of 42-97 % for all analytes. The findings reveal that the QuEChERS method offers a higher extraction efficiency, yielding cleaner samples with greater purity and preferred choice for drug analysis in forensic toxicology. The results showed that the proposed technique has a good analytical efficiency and the accuracy of work is in the average range of 70-85 %. The equation of linear calibration curve was obtained with regression coefficient > 0.99. Detection limits were in the range of 0.21-0.38 ng/mL.•This method is inexpensive and fast for determination of antiepileptic drugs in serum•This method has high thought of sample determination.•This method is green chemistry method.

Authors

Institutions

Publication Details

Journal
MethodsX
Published
2025-05-08
DOI
https://doi.org/10.1016/j.mex.2025.103353
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modified QuEChERS for antiepileptic drugs detection in forensic toxicology

Masoud Ghadipasha, Mohammad Kazem Koohi, Ahmad Shekari, Jalal Hassan et al.
MethodsX
Analytical chemistry methods development
article

Modified QuEChERS for antiepileptic drugs detection in forensic toxicology

Masoud Ghadipasha, Mohammad Kazem Koohi, Ahmad Shekari, Jalal Hassan, Maryam Akhgari
article en

Abstract

This study aims to concurrently assess the blood concentrations of antiepileptic drugs including phenobarbital, carbamazepine, primidone, phenytoin in post-mortem samples through the application modified QuEChERS extraction. The serum samples were extracted and then purified using magnesium sulfate, PSA, and C18 sorbents and subsequently analyzed using HPLC/UV. One influencing parameter on the extraction process was the pH of sample. Extraction recoveries were in the range of 42-97 % for all analytes. The findings reveal that the QuEChERS method offers a higher extraction efficiency, yielding cleaner samples with greater purity and preferred choice for drug analysis in forensic toxicology. The results showed that the proposed technique has a good analytical efficiency and the accuracy of work is in the average range of 70-85 %. The equation of linear calibration curve was obtained with regression coefficient > 0.99. Detection limits were in the range of 0.21-0.38 ng/mL.•This method is inexpensive and fast for determination of antiepileptic drugs in serum•This method has high thought of sample determination.•This method is green chemistry method.

MethodsXVol. 14
University of Tehran (IR), Iranian Legal Medicine Organization (IR)
Openalex Percentile: Top 89%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.