Validation and moisture content sensitivity analysis of cross-laminated timber wall assemblies in EnergyPlus

Cross-laminated timber buildings are becoming more common in North America, with many numerical studies showing potential energy savings. However, no studies have validated any EnergyPlus heat transfer algorithms or quantified their accuracy in simulating CLT in building envelopes. This study empirically validates the heat flux predictions for each of EnergyPlus's heat transfer algorithms (Conduction Transfer Functions (CTF), Effective Moisture Penetration Depth (EMPD), Conduction Finite Difference (CondFD), and Heat and Moisture Transfer (HAMT)) for two different CLT ply thicknesses with both summer and winter boundary conditions measured in controlled lab experiments. It also evaluates the model sensitivity of heat flux and heating and cooling loads to moisture content. The 1D validation shows that the HAMT model is the most accurate among all algorithms. All EnergyPlus's heat flux predictions are accurate independent of CLT plate thickness for summer conditions. However, the three constant property algorithms (CTF, EMPD, and CondFD) underpredict heat flux throughout the whole day during winter conditions. The 1D sensitivity analysis indicates that elevated moisture content can increase peak heat fluxes through the material by up to 20 %. Finally, the whole building model sensitivity analysis shows increased heating load and slight cooling load variation due to increased moisture content when using constant property models. The analysis shows significantly lower peak thermal demand (7 % lower heating and 6 % lower cooling) and monthly thermal load (8 % less cooling and 6 % less heating) predictions when using HAMT vs a constant property model. • Empirically validate EnergyPlus' heat flux algorithms with two CLT samples. • Sensitivity evaluation of heat flux to the moisture content. • Validation shows HAMT provides most accurate results in both winter and summer. • Property variations to moisture content and physics add uncertainty to results.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2025-05-08
DOI
https://doi.org/10.1016/j.jobe.2025.112852
Citations
1
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation and moisture content sensitivity analysis of cross-laminated timber wall assemblies in EnergyPlus

Gabriel Flechas, Paulo Cesar Tabares-Velasco, Mikael Salonvaara
1 citations
Journal of Building Engineering
Wood Treatment and Properties
1.01
article

Validation and moisture content sensitivity analysis of cross-laminated timber wall assemblies in EnergyPlus

Gabriel Flechas, Paulo Cesar Tabares-Velasco, Mikael Salonvaara
article en
1 citations

Abstract

Cross-laminated timber buildings are becoming more common in North America, with many numerical studies showing potential energy savings. However, no studies have validated any EnergyPlus heat transfer algorithms or quantified their accuracy in simulating CLT in building envelopes. This study empirically validates the heat flux predictions for each of EnergyPlus's heat transfer algorithms (Conduction Transfer Functions (CTF), Effective Moisture Penetration Depth (EMPD), Conduction Finite Difference (CondFD), and Heat and Moisture Transfer (HAMT)) for two different CLT ply thicknesses with both summer and winter boundary conditions measured in controlled lab experiments. It also evaluates the model sensitivity of heat flux and heating and cooling loads to moisture content. The 1D validation shows that the HAMT model is the most accurate among all algorithms. All EnergyPlus's heat flux predictions are accurate independent of CLT plate thickness for summer conditions. However, the three constant property algorithms (CTF, EMPD, and CondFD) underpredict heat flux throughout the whole day during winter conditions. The 1D sensitivity analysis indicates that elevated moisture content can increase peak heat fluxes through the material by up to 20 %. Finally, the whole building model sensitivity analysis shows increased heating load and slight cooling load variation due to increased moisture content when using constant property models. The analysis shows significantly lower peak thermal demand (7 % lower heating and 6 % lower cooling) and monthly thermal load (8 % less cooling and 6 % less heating) predictions when using HAMT vs a constant property model. • Empirically validate EnergyPlus' heat flux algorithms with two CLT samples. • Sensitivity evaluation of heat flux to the moisture content. • Validation shows HAMT provides most accurate results in both winter and summer. • Property variations to moisture content and physics add uncertainty to results.

Journal of Building EngineeringVol. 108
Oak Ridge National Laboratory (US), Colorado School of Mines (US)
Openalex Percentile: Top 25%
Wood Treatment and Properties
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.