Mechanical Investigation on the Foot Orthosis of Carbon Fiber (CF) Based on the Dynamic Loads: A Finite Element Analysis

In this comprehensive study, a sophisticated finite element analysis (FEA) methodology was employed to investigate the mechanical properties of a foot orthosis meticulously crafted from carbon fiber (CF). The primary focus of this research centers around the dynamic loads exerted on the orthosis during various activities. Utilizing a static structural analysis tool, we meticulously configured both the pre-analysis and post-analysis phases of the simulation process, which specifically addressed the behavior of the fiber optic (FO) within the carbon fiber material. A critical component of this investigation involved a convergence study based on a thorough deformation analysis, which allowed for an in-depth exploration of unique stress types that impact the orthosis. The range of stresses analyzed included not only von Mises stress but also various other typical stress categories relevant to the device's structural integrity. Furthermore, the research delved into the magnitude and implications of these stress levels, contributing to a comprehensive understanding of the orthosis's performance under load. To achieve a complete analysis of the current scenario, a detailed examination of the overall deformation of the orthosis was undertaken. Remarkably, the findings revealed that the maximum deformation experienced at the tip of the foot reached an incredibly minute measurement of just 0.001 millimeters. The crucial numerical findings for von Mises stress indicated a value of 19.1 MPa, providing valuable insights into the material's limitations. The simulation results highlighted that the concentration of stress primarily occurs in the regions of the foot located behind the heel, shedding light on potential areas for further optimization and design enhancement.

Authors

Publication Details

Journal
International Journal on Advanced Science Engineering and Information Technology
Published
2025-04-27
DOI
https://doi.org/10.18517/ijaseit.15.2.12616
Primary Topic
Mechanical Engineering and Vibrations Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Investigation on the Foot Orthosis of Carbon Fiber (CF) Based on the Dynamic Loads: A Finite Element Analysis

Hussein Kadhim Sharaf, Basim A. Sadkhan, Hayder Mohammed Kadhim, Rusul Salah Hadi
2 links
International Journal on Advanced Science Engineering and Information Technology
Mechanical Engineering and Vibrations Research
article

Mechanical Investigation on the Foot Orthosis of Carbon Fiber (CF) Based on the Dynamic Loads: A Finite Element Analysis

Hussein Kadhim Sharaf, Basim A. Sadkhan, Hayder Mohammed Kadhim, Rusul Salah Hadi
article en

Abstract

In this comprehensive study, a sophisticated finite element analysis (FEA) methodology was employed to investigate the mechanical properties of a foot orthosis meticulously crafted from carbon fiber (CF). The primary focus of this research centers around the dynamic loads exerted on the orthosis during various activities. Utilizing a static structural analysis tool, we meticulously configured both the pre-analysis and post-analysis phases of the simulation process, which specifically addressed the behavior of the fiber optic (FO) within the carbon fiber material. A critical component of this investigation involved a convergence study based on a thorough deformation analysis, which allowed for an in-depth exploration of unique stress types that impact the orthosis. The range of stresses analyzed included not only von Mises stress but also various other typical stress categories relevant to the device's structural integrity. Furthermore, the research delved into the magnitude and implications of these stress levels, contributing to a comprehensive understanding of the orthosis's performance under load. To achieve a complete analysis of the current scenario, a detailed examination of the overall deformation of the orthosis was undertaken. Remarkably, the findings revealed that the maximum deformation experienced at the tip of the foot reached an incredibly minute measurement of just 0.001 millimeters. The crucial numerical findings for von Mises stress indicated a value of 19.1 MPa, providing valuable insights into the material's limitations. The simulation results highlighted that the concentration of stress primarily occurs in the regions of the foot located behind the heel, shedding light on potential areas for further optimization and design enhancement.

International Journal on Advanced Science Engineering and Information TechnologyVol. 15(2)
Openalex Percentile: Top 91%
Mechanical Engineering and Vibrations Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.