Artificial intelligence in chromatography: Greenness and performance evaluation of AI-predicted and in-lab optimized HPLC methods for simultaneous separation of amlodipine, hydrochlorothiazide, and candesartan

• AI-assisted HPLC predictions required human refinement for practical application. • AI-generated conditions resulted in longer retention times and higher solvent use. • The developed HPLC method significantly reduced solvent consumption and analysis time. • The optimized In-Lab method was validated and applied successfully to pharmaceutical formulations. • The environmental assessment revealed the optimized HPLC method’s superior greenness over the AI-predicted method. • The study highlights AI's potential but underscores the necessity of human expertise. Artificial Intelligence (AI) is revolutionizing analytical chemistry by promising rapid method development, yet its real-world efficacy remains untested in complex pharmaceutical separations. This study leverages AI to design an HPLC method for Amlodipine (AMD), Hydrochlorothiazide (HYD), and Candesartan (CND), comparing it with an experimentally optimized approach to uncover practical benefits and limitations. Our findings reveal AI’s potential to accelerate innovation while highlighting the critical role of human expertise. The In-Lab optimized HPLC method utilized an Xselect CSH Phenyl Hexyl® (2.5 µm, 4.6 × 150 mm) column with a mobile phase of acetonitrile:water (0.1% trifluoroacetic acid) (70:30, v/v), a flow rate of 1.3 mL/min, and UV detection at 250 nm. It achieved rapid elution with retention times of AMD = 0.95 min, HYD = 1.36 min, and CND = 2.82 min. The AI-generated method used a C18 column (5 µm, 150 mm × 4.6 mm), gradient elution with phosphate buffer (pH 3.0) and acetonitrile, a flow rate of 1.0 mL/min, and detection at 240 nm, resulting in longer retention times: AMD = 7.12 min, HYD = 3.98 min, and CND = 12.12 min. Linearity ranges were AMD (25.0–150.0 µg/mL), HYD (31.2–187.0 µg/mL), and CND (40.0–240.0 µg/mL) for the In-Lab method, and AMD (30.0–150.0 µg/mL), HYD (35.0–185.0 µg/mL), and CND (50.0–240.0 µg/mL) for the AI method. Both approaches were validated per ICH guidelines, confirming specificity, accuracy, and reliability. The obtained results were statistically compared with the reported ones using the F-test and Student’s t-test. In terms of sustainability, the In-Lab method outperformed the AI-based method according to MoGAPI, AGREE, and BAGI assessments, due to reduced solvent use, waste generation, and analysis time. This study underscores the necessity of human intervention to refine AI-generated methods, aligning them with both analytical efficiency and green chemistry goals. Improving AI tools to predict optimal HPLC conditions is essential for advancing sustainable and effective analytical practices.

Authors

Institutions

Publication Details

Journal
Talanta Open
Published
2025-05-08
DOI
https://doi.org/10.1016/j.talo.2025.100473
Citations
10
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
7.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial intelligence in chromatography: Greenness and performance evaluation of AI-predicted and in-lab optimized HPLC methods for simultaneous separation of amlodipine, hydrochlorothiazide, and candesartan

Gizem Tırıs, Reem H. Obaydo, Nevin Erk, Asena Ayse Genc et al.
10 citations
Talanta Open
Analytical Methods in Pharmaceuticals
7.52
article

Artificial intelligence in chromatography: Greenness and performance evaluation of AI-predicted and in-lab optimized HPLC methods for simultaneous separation of amlodipine, hydrochlorothiazide, and candesartan

Gizem Tırıs, Reem H. Obaydo, Nevin Erk, Asena Ayse Genc, Hayam M. Lotfy
article en
10 citations

Abstract

• AI-assisted HPLC predictions required human refinement for practical application. • AI-generated conditions resulted in longer retention times and higher solvent use. • The developed HPLC method significantly reduced solvent consumption and analysis time. • The optimized In-Lab method was validated and applied successfully to pharmaceutical formulations. • The environmental assessment revealed the optimized HPLC method’s superior greenness over the AI-predicted method. • The study highlights AI's potential but underscores the necessity of human expertise. Artificial Intelligence (AI) is revolutionizing analytical chemistry by promising rapid method development, yet its real-world efficacy remains untested in complex pharmaceutical separations. This study leverages AI to design an HPLC method for Amlodipine (AMD), Hydrochlorothiazide (HYD), and Candesartan (CND), comparing it with an experimentally optimized approach to uncover practical benefits and limitations. Our findings reveal AI’s potential to accelerate innovation while highlighting the critical role of human expertise. The In-Lab optimized HPLC method utilized an Xselect CSH Phenyl Hexyl® (2.5 µm, 4.6 × 150 mm) column with a mobile phase of acetonitrile:water (0.1% trifluoroacetic acid) (70:30, v/v), a flow rate of 1.3 mL/min, and UV detection at 250 nm. It achieved rapid elution with retention times of AMD = 0.95 min, HYD = 1.36 min, and CND = 2.82 min. The AI-generated method used a C18 column (5 µm, 150 mm × 4.6 mm), gradient elution with phosphate buffer (pH 3.0) and acetonitrile, a flow rate of 1.0 mL/min, and detection at 240 nm, resulting in longer retention times: AMD = 7.12 min, HYD = 3.98 min, and CND = 12.12 min. Linearity ranges were AMD (25.0–150.0 µg/mL), HYD (31.2–187.0 µg/mL), and CND (40.0–240.0 µg/mL) for the In-Lab method, and AMD (30.0–150.0 µg/mL), HYD (35.0–185.0 µg/mL), and CND (50.0–240.0 µg/mL) for the AI method. Both approaches were validated per ICH guidelines, confirming specificity, accuracy, and reliability. The obtained results were statistically compared with the reported ones using the F-test and Student’s t-test. In terms of sustainability, the In-Lab method outperformed the AI-based method according to MoGAPI, AGREE, and BAGI assessments, due to reduced solvent use, waste generation, and analysis time. This study underscores the necessity of human intervention to refine AI-generated methods, aligning them with both analytical efficiency and green chemistry goals. Improving AI tools to predict optimal HPLC conditions is essential for advancing sustainable and effective analytical practices.

Talanta OpenVol. 11
Cairo University (EG), Ankara University (TR), Bezmiâlem Vakıf Üniversitesi (TR), Syrian Private University (SY)
Openalex Percentile: Top 2%
Analytical Methods in Pharmaceuticals
7.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.