Predictors of right ventricular failure in patients after left ventricular assist device implantation

Background. To determine predictors of early and late right ventricular failure (RVF) according to transthoracic echocardiography (TTEchoCG) and right heart catheterisation (RHC) in patients with left ventricular assist device (LVAD). Materials and methods. Twenty-three patients with LVAD were included in the study. Before implantation, all patients underwent TTEchoCG with comprehensive evaluation of the right ventricle (RV) using speckle-tracking echocardiography (STE) and 3D-echocardiography (3D-RVEF), as well as RHC with measurement of standard indices and calculation of pulmonary artery pulsatility index (PAPi). Results. The highest area under the ROC curve was the RV ejection fraction determined by 3D-RVEF (0.841 with 95% CI 0.677–1.006, sensitivity 0.889, specificity 0.786; p0.001) with a cut-off value ≤42% (OR 29.3 with 95% CI 2.6–336.4; p=0.007) and PAPi (area on ROC curve 0.869 with 95% CI 0.503–0.975, sensitivity 0.778, specificity 0.857; p0.001,) with a threshold value ≤2.2 (OR 20 with 95% CI 1.2–333.3; p=0.035). The combination of these parameters was the most accurate prognostic model (sensitivity 0.778, specificity 1). The combination of echocardiographic parameters – 3D-RVEF and systolic velocity of the tricuspid valve fibrous ring according to tissue myocardial Doppler (TMD: S’ml) has similar sensitivity (0.778) and slightly lower specificity (0.929). Conclusion. The optimal independent echocardiographic predictor of early RVF is 3D-RVEF. The combination of 3D-RVEF and PAPi proved to be the most accurate model, but the combination of 3D-RVEF and S’ml-TMD echocardiographic parameters alone is only slightly inferior in specificity, which allows preliminary assessment of the risk of RVF.

Authors

Institutions

Publication Details

Journal
Terapevticheskii arkhiv
Published
2025-05-08
DOI
https://doi.org/10.26442/00403660.2025.04.203169
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predictors of right ventricular failure in patients after left ventricular assist device implantation

I. A. Merkulova, A.A. Shiryaev, O. Yu. Narusov, М. А. Саидова et al.
Terapevticheskii arkhiv
Mechanical Circulatory Support Devices
article

Predictors of right ventricular failure in patients after left ventricular assist device implantation

I. A. Merkulova, A.A. Shiryaev, O. Yu. Narusov, М. А. Саидова, М. И. Макеев, С. Н. Терещенко, Д. В. Певзнер, Е. В. Дзыбинская, K. G. Ganaev, С.М. Смирнов, Janna A. Shahramanova
article en

Abstract

Background. To determine predictors of early and late right ventricular failure (RVF) according to transthoracic echocardiography (TTEchoCG) and right heart catheterisation (RHC) in patients with left ventricular assist device (LVAD). Materials and methods. Twenty-three patients with LVAD were included in the study. Before implantation, all patients underwent TTEchoCG with comprehensive evaluation of the right ventricle (RV) using speckle-tracking echocardiography (STE) and 3D-echocardiography (3D-RVEF), as well as RHC with measurement of standard indices and calculation of pulmonary artery pulsatility index (PAPi). Results. The highest area under the ROC curve was the RV ejection fraction determined by 3D-RVEF (0.841 with 95% CI 0.677–1.006, sensitivity 0.889, specificity 0.786; p0.001) with a cut-off value ≤42% (OR 29.3 with 95% CI 2.6–336.4; p=0.007) and PAPi (area on ROC curve 0.869 with 95% CI 0.503–0.975, sensitivity 0.778, specificity 0.857; p0.001,) with a threshold value ≤2.2 (OR 20 with 95% CI 1.2–333.3; p=0.035). The combination of these parameters was the most accurate prognostic model (sensitivity 0.778, specificity 1). The combination of echocardiographic parameters – 3D-RVEF and systolic velocity of the tricuspid valve fibrous ring according to tissue myocardial Doppler (TMD: S’ml) has similar sensitivity (0.778) and slightly lower specificity (0.929). Conclusion. The optimal independent echocardiographic predictor of early RVF is 3D-RVEF. The combination of 3D-RVEF and PAPi proved to be the most accurate model, but the combination of 3D-RVEF and S’ml-TMD echocardiographic parameters alone is only slightly inferior in specificity, which allows preliminary assessment of the risk of RVF.

Terapevticheskii arkhivVol. 97(04)
National Medical Research Center of Cardiology (RU)
Openalex Percentile: Top 91%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.