Performance Study of a NH3/LiNO3 Absorption Chiller Under South Algerian Climate

This study investigates the feasibility of implementing an NH3/LiNO3 absorption chiller under the climatic conditions of Bechar, Algeria. Using energy and exergy analysis techniques, the research evaluates the system's performance under various operating conditions. The absorption cycle is modeled using Engineering Equation Solver (EES) to assess the impact of key parameters on the coefficient of performance (COP). Results indicate that the COP is significantly influenced by generator, condenser, and absorber temperatures. The COP increases from 0.10 to 0.524 as the generator inlet heating water temperature rises, and from 0.10 to 0.628 with increasing absorber temperature. However, the COP decreases from 0.58 to 0.31 as the evaporator temperature increases, and from 0.627 to 0.202 with increasing condenser temperature. The study contributes to ongoing efforts to develop sustainable cooling solutions tailored to regions with extreme climates, highlighting the potential of NH3/LiNO3 absorption chillers for solar-driven cooling applications in hot and arid environments like southern Algeria.

Authors

Institutions

Publication Details

Journal
Metallurgical and Materials Engineering
Published
2025-04-16
DOI
https://doi.org/10.63278/1515
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Study of a NH3/LiNO3 Absorption Chiller Under South Algerian Climate

Brahim Mebarki, Belkacem Draoui, A. Roukbi
Metallurgical and Materials Engineering
Adsorption and Cooling Systems
article

Performance Study of a NH3/LiNO3 Absorption Chiller Under South Algerian Climate

Brahim Mebarki, Belkacem Draoui, A. Roukbi
article en

Abstract

This study investigates the feasibility of implementing an NH3/LiNO3 absorption chiller under the climatic conditions of Bechar, Algeria. Using energy and exergy analysis techniques, the research evaluates the system's performance under various operating conditions. The absorption cycle is modeled using Engineering Equation Solver (EES) to assess the impact of key parameters on the coefficient of performance (COP). Results indicate that the COP is significantly influenced by generator, condenser, and absorber temperatures. The COP increases from 0.10 to 0.524 as the generator inlet heating water temperature rises, and from 0.10 to 0.628 with increasing absorber temperature. However, the COP decreases from 0.58 to 0.31 as the evaporator temperature increases, and from 0.627 to 0.202 with increasing condenser temperature. The study contributes to ongoing efforts to develop sustainable cooling solutions tailored to regions with extreme climates, highlighting the potential of NH3/LiNO3 absorption chillers for solar-driven cooling applications in hot and arid environments like southern Algeria.

Metallurgical and Materials EngineeringVol. 31(4)
University of Bechar (DZ)
Openalex Percentile: Top 91%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Study of a NH3/LiNO3 Absorption Chiller Under South Algerian Climate — Brahim Mebarki, Belkacem Draoui, et al. · Metallurgical and Materials Engineering (2025) | TGRS Research Map | TGRS