Design, Construction and Validation of a Low Cost Resonance “Futamag” Magnetometer

The cost of new magnetometers has gone up astronomically and consequently many institutions that need this equipment for teaching and research purposes can hardly afford the price. This predicament compelled the authors to look for electronic components that are available in local markets and shops to fabricate this magnetometer. This magnetometer was designed and constructed using components purchased locally. Construction, Configuration and Standardization of ‘Futamag’ Resonance Magnetometer was done with appropriate validations in the basement complex terrain characterized with crystalline bedrock geologic terrain. ‘Futamag’ Resonance magnetometer and Unimag, as a standard equipment, were used to acquire magnetic data concurrently along the six established traverses at Senior Staff quarters, Federal University of Technology, Akure. Regression analysis was carried out as basis for relative standardization of ‘Futamag’ Resonance Magnetometer by subjecting the data acquired to series of processing and interpretations to test the reliability of the newly constructed magnetometer. The data obtained were interpreted qualitatively by profile correlation using percentage relative trend appraisals and quantitatively, by using half-width method to determine depth to the top of basement. The estimated depths showed a good correlation with little disparity experienced along some traverses. The difference cannot be completely associated to deficiency from ‘Futamag’ but may be as a result of poor control over environmental noise on the part of the ‘Futamag’. Higher level of correlation between the ‘Futamag’ and Unimag Resonance Magnetometers was achieved from the regression analysis with 99% reliability which justifies that construction of resonance magnetometer can be done with locally available materials using appropriate standardization.

Authors

Institutions

Publication Details

Journal
Applied sciences research periodicals.
Published
2025-05-05
DOI
https://doi.org/10.63002/asrp.303.484
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design, Construction and Validation of a Low Cost Resonance “Futamag” Magnetometer

Olufemi Adigun Alagbe, Timothy Olutunde Adedeji, Pius Adekunle Enikanselu
1 links
Applied sciences research periodicals.
Magnetic Field Sensors Techniques
article

Design, Construction and Validation of a Low Cost Resonance “Futamag” Magnetometer

Olufemi Adigun Alagbe, Timothy Olutunde Adedeji, Pius Adekunle Enikanselu
article en

Abstract

The cost of new magnetometers has gone up astronomically and consequently many institutions that need this equipment for teaching and research purposes can hardly afford the price. This predicament compelled the authors to look for electronic components that are available in local markets and shops to fabricate this magnetometer. This magnetometer was designed and constructed using components purchased locally. Construction, Configuration and Standardization of ‘Futamag’ Resonance Magnetometer was done with appropriate validations in the basement complex terrain characterized with crystalline bedrock geologic terrain. ‘Futamag’ Resonance magnetometer and Unimag, as a standard equipment, were used to acquire magnetic data concurrently along the six established traverses at Senior Staff quarters, Federal University of Technology, Akure. Regression analysis was carried out as basis for relative standardization of ‘Futamag’ Resonance Magnetometer by subjecting the data acquired to series of processing and interpretations to test the reliability of the newly constructed magnetometer. The data obtained were interpreted qualitatively by profile correlation using percentage relative trend appraisals and quantitatively, by using half-width method to determine depth to the top of basement. The estimated depths showed a good correlation with little disparity experienced along some traverses. The difference cannot be completely associated to deficiency from ‘Futamag’ but may be as a result of poor control over environmental noise on the part of the ‘Futamag’. Higher level of correlation between the ‘Futamag’ and Unimag Resonance Magnetometers was achieved from the regression analysis with 99% reliability which justifies that construction of resonance magnetometer can be done with locally available materials using appropriate standardization.

Applied sciences research periodicals.Vol. 3(03)
Federal University of Technology (NG)
Openalex Percentile: Top 92%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design, Construction and Validation of a Low Cost Resonance “Futamag” Magnetometer — Olufemi Adigun Alagbe, Timothy Olutunde Adedeji, et al. · Applied sciences research periodicals. (2025) | TGRS Research Map | TGRS