Analysis of factors affecting the tip position of a tunneled cuffed catheter using the thoracic surface marker method

Catheterization methods use the lower margin of the right third intercostal space to predict the catheter tip position; however, adjustments are often necessary. We evaluated the catheter position and surface markers of the chest and the relevant factors that affect the position and depth of the catheter tip. This single-center, cross-sectional study included 173 patients who underwent right internal jugular vein tunnel insertion with a tunneled cuffed catheter (TCC). The sternal length, intercostal width, anterior-to-posterior sternal diameter, and transverse diameter of the thorax were recorded, and the thoracic aspect ratio was calculated. The cardiothoracic ratio and position of the catheter tip were measured using chest computed tomography. The correct placement was when the catheter tip was in the upper 1/3 of the right atrium (deep group: below the correct placement; shallow group: above the correct placement). Catheter tip indices were subjected to logistic regression analyses. A receiver operating characteristic (ROC) curve was used to assess the risk and optimal cutoff of the catheter tip depth. There were significant differences in sternum length, cardiothoracic ratio, anterior-to-posterior thoracic diameter, and thoracic aspect ratio between the groups (<i>p</i> < 0.05). The latter three variables were influencing factors for catheter tip depth (<i>p</i> < 0.05). The anterior-to-posterior thoracic diameter (<i>p</i> = 0.003; cutoff, 22.5 cm; ROC, 0.695) and thoracic aspect ratio (<i>p</i> = 0.014; cutoff, 0.74; ROC, 0.632) were independent risk factors for catheter tip depth and position, respectively. The position of the TCC catheter tip was related to the sternal length, anterior-to-posterior thoracic diameter, thoracic aspect ratio, and cardiothoracic ratio.

Authors

Institutions

Publication Details

Journal
Renal Failure
Published
2025-05-06
DOI
https://doi.org/10.1080/0886022x.2025.2496435
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of factors affecting the tip position of a tunneled cuffed catheter using the thoracic surface marker method

Zeyao Shi, Shuzhong Duan, Ce Liu, Sijia Ma et al.
Renal Failure
Central Venous Catheters and Hemodialysis
article

Analysis of factors affecting the tip position of a tunneled cuffed catheter using the thoracic surface marker method

Zeyao Shi, Shuzhong Duan, Ce Liu, Sijia Ma, Yan Huang, Huanhuan Wang, Xiaojing Zhao
article en

Abstract

Catheterization methods use the lower margin of the right third intercostal space to predict the catheter tip position; however, adjustments are often necessary. We evaluated the catheter position and surface markers of the chest and the relevant factors that affect the position and depth of the catheter tip. This single-center, cross-sectional study included 173 patients who underwent right internal jugular vein tunnel insertion with a tunneled cuffed catheter (TCC). The sternal length, intercostal width, anterior-to-posterior sternal diameter, and transverse diameter of the thorax were recorded, and the thoracic aspect ratio was calculated. The cardiothoracic ratio and position of the catheter tip were measured using chest computed tomography. The correct placement was when the catheter tip was in the upper 1/3 of the right atrium (deep group: below the correct placement; shallow group: above the correct placement). Catheter tip indices were subjected to logistic regression analyses. A receiver operating characteristic (ROC) curve was used to assess the risk and optimal cutoff of the catheter tip depth. There were significant differences in sternum length, cardiothoracic ratio, anterior-to-posterior thoracic diameter, and thoracic aspect ratio between the groups (<i>p</i> < 0.05). The latter three variables were influencing factors for catheter tip depth (<i>p</i> < 0.05). The anterior-to-posterior thoracic diameter (<i>p</i> = 0.003; cutoff, 22.5 cm; ROC, 0.695) and thoracic aspect ratio (<i>p</i> = 0.014; cutoff, 0.74; ROC, 0.632) were independent risk factors for catheter tip depth and position, respectively. The position of the TCC catheter tip was related to the sternal length, anterior-to-posterior thoracic diameter, thoracic aspect ratio, and cardiothoracic ratio.

Renal FailureVol. 47(1)
Chengde Medical University (CN)
Openalex Percentile: Top 84%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.