Control of Microplastics and Nanoplastics Discharge via Biochar‐Based Filtration: Optimization Using Central Composite Design (CCD) and Identification of Column Fouling Mechanism

ABSTRACT Microplastics (MPs) and nanoplastics (NPs) are emerging aquatic pollutants of significant environmental concern due to their pervasive hazards. Filtration using filter media is a common approach for mitigating MP and NP contamination; however, the optimization of process parameters and the underlying column fouling mechanisms remains insufficiently explored. This study investigates the optimization of MP and NP removal using surface‐engineered biochar in a continuous‐flow column system via response surface methodology (RSM) employing central composite design (CCD). Four operating parameters were evaluated: pH (3–11), MP and NP concentration (0.01–0.09 g/L), flow rate (5–9 mL/min), and biochar bed depth (5–15 cm). Optimal removal efficiency was achieved at pH 7, MP and NP concentration of 0.01 g/L, 7 mL/min flow rate, and 10 cm biochar bed depth, yielding removal efficiencies of 93.75% (measured by turbidity method) and 93.07% (estimated by gravimetric method). Analysis of variance (ANOVA) confirmed the model's significance, with a high coefficient of determination ( R 2 ) observed between predicted and actual data. All tested parameters and two interacting parameters, (i) concentration‐flow rate and (ii) flow rate‐biochar bed depth, significantly influenced MP and NP removal efficiency. Prolonged operation under optimal conditions induced fouling of biochar‐packed bed, and an evaluation using Hermia's model, assuming uniform bed porosity and filtration as the main removal mechanism, indicated the presence of standard blocking, intermediate blocking, and cake filtration as primary fouling mechanisms. This study highlights the potential of surface‐engineered biochar as a promising filter media for efficient MP and NP removal while providing insights into the column fouling dynamics.

Authors

Institutions

Publication Details

Journal
Environmental Quality Management
Published
2025-05-06
DOI
https://doi.org/10.1002/tqem.70098
Citations
3
Primary Topic
Recycling and Waste Management Techniques
Type
article
Field-Weighted Citation Impact
2.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Control of Microplastics and Nanoplastics Discharge via Biochar‐Based Filtration: Optimization Using Central Composite Design (CCD) and Identification of Column Fouling Mechanism

Nabilah Aminah Lutpi, Mohamed Hasnain Isa, Muhammad Adli Hanif, Naimah Ibrahim et al.
3 citations
Environmental Quality Management
Recycling and Waste Management Techniques
2.99
article

Control of Microplastics and Nanoplastics Discharge via Biochar‐Based Filtration: Optimization Using Central Composite Design (CCD) and Identification of Column Fouling Mechanism

Nabilah Aminah Lutpi, Mohamed Hasnain Isa, Muhammad Adli Hanif, Naimah Ibrahim, Farrah Aini Dahalan, Ayu Wazira Azhari, Umi Fazara Md Ali, Masitah Hasan
article en
3 citations

Abstract

ABSTRACT Microplastics (MPs) and nanoplastics (NPs) are emerging aquatic pollutants of significant environmental concern due to their pervasive hazards. Filtration using filter media is a common approach for mitigating MP and NP contamination; however, the optimization of process parameters and the underlying column fouling mechanisms remains insufficiently explored. This study investigates the optimization of MP and NP removal using surface‐engineered biochar in a continuous‐flow column system via response surface methodology (RSM) employing central composite design (CCD). Four operating parameters were evaluated: pH (3–11), MP and NP concentration (0.01–0.09 g/L), flow rate (5–9 mL/min), and biochar bed depth (5–15 cm). Optimal removal efficiency was achieved at pH 7, MP and NP concentration of 0.01 g/L, 7 mL/min flow rate, and 10 cm biochar bed depth, yielding removal efficiencies of 93.75% (measured by turbidity method) and 93.07% (estimated by gravimetric method). Analysis of variance (ANOVA) confirmed the model's significance, with a high coefficient of determination ( R 2 ) observed between predicted and actual data. All tested parameters and two interacting parameters, (i) concentration‐flow rate and (ii) flow rate‐biochar bed depth, significantly influenced MP and NP removal efficiency. Prolonged operation under optimal conditions induced fouling of biochar‐packed bed, and an evaluation using Hermia's model, assuming uniform bed porosity and filtration as the main removal mechanism, indicated the presence of standard blocking, intermediate blocking, and cake filtration as primary fouling mechanisms. This study highlights the potential of surface‐engineered biochar as a promising filter media for efficient MP and NP removal while providing insights into the column fouling dynamics.

Environmental Quality ManagementVol. 34(4)
Universiti Teknologi Brunei (BN), Universiti Malaysia Perlis (MY)
Ministry of Higher Education, Malaysia, Universiti Malaysia Perlis
Openalex Percentile: Top 10%
Recycling and Waste Management Techniques
2.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.