Simultaneous quantification of Empagliflozin and Metformin in pharmaceutical dosage form using HPLC technique

A reversed-phase high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous quantification of empagliflozin and metformin in their combined dosage form. The analysis was performed on an Agilent 1200 system equipped with a diode array detector (DAD) using a Hypersil BDS C18 column (4.6 mm x 15 cm, 5 μm). The mobile phase consisted of an isocratic 70:30 (v/v) mixture of phosphate buffer (prepared by dissolving 6.8 g potassium dihydrogen orthophosphate in 1 L water and filtered with a 0.45 μm nylon filter) and acetonitrile. The flow rate was set to 1.5 mL/min, and the injection volume for both empagliflozin and metformin was 10 μL. Detection was performed at 255 nm using the DAD. The method demonstrated linearity over concentration ranges of 3.125-9.38 μg/mL for empagliflozin (retention time: 6.4 min) and 250-750 μg/mL for metformin (retention time: 2.6 min) with correlation coefficients exceeding 0.999. The relative standard deviation (RSD) was less than 2%. These results demonstrate that the method is rapid, accurate, precise, and sensitive, making it suitable for routine quality control of tablets containing both drugs in pharmaceutical settings

Authors

Institutions

Publication Details

Journal
Bulletin of Faculty of Science Zagazig University
Published
2025-04-01
DOI
https://doi.org/10.21608/bfszu.2025.294373.1396
Primary Topic
Diabetes Treatment and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous quantification of Empagliflozin and Metformin in pharmaceutical dosage form using HPLC technique

Alaa S. Amin, Mourad Abo-Taleb, Soha F. Mohammed
Bulletin of Faculty of Science Zagazig University
Diabetes Treatment and Management
article

Simultaneous quantification of Empagliflozin and Metformin in pharmaceutical dosage form using HPLC technique

Alaa S. Amin, Mourad Abo-Taleb, Soha F. Mohammed
article en

Abstract

A reversed-phase high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous quantification of empagliflozin and metformin in their combined dosage form. The analysis was performed on an Agilent 1200 system equipped with a diode array detector (DAD) using a Hypersil BDS C18 column (4.6 mm x 15 cm, 5 μm). The mobile phase consisted of an isocratic 70:30 (v/v) mixture of phosphate buffer (prepared by dissolving 6.8 g potassium dihydrogen orthophosphate in 1 L water and filtered with a 0.45 μm nylon filter) and acetonitrile. The flow rate was set to 1.5 mL/min, and the injection volume for both empagliflozin and metformin was 10 μL. Detection was performed at 255 nm using the DAD. The method demonstrated linearity over concentration ranges of 3.125-9.38 μg/mL for empagliflozin (retention time: 6.4 min) and 250-750 μg/mL for metformin (retention time: 2.6 min) with correlation coefficients exceeding 0.999. The relative standard deviation (RSD) was less than 2%. These results demonstrate that the method is rapid, accurate, precise, and sensitive, making it suitable for routine quality control of tablets containing both drugs in pharmaceutical settings

Bulletin of Faculty of Science Zagazig UniversityVol. 2025(1)
Zagazig University (EG), Benha University (EG)
Openalex Percentile: Top 87%
Diabetes Treatment and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.