RESPIRATORY MUSCLE ULTRASOUND VERSUS RAPID SHALLOW BREATHING INDEX AS A WEANING PREDICTOR IN PROLONGED MECHANICALLY VENTILATED PATIENTS.

Mechanical ventilation is a life-saving intervention in intensive care units (ICUs), but prolonged use can lead to complications such as ventilator-induced diaphragmatic dysfunction (VIDD) and increased mortality. Weaning patients from mechanical ventilation is a critical process, with approximately 15% of patients requiring reintubation within 48 hours. Traditional weaning predictors, like the Rapid Shallow Breathing Index (RSBI), have limitations in accuracy. Respiratory muscle ultrasound, particularly diaphragmatic and parasternal intercostal muscle thickening fractions, offers a non-invasive, real-time method to assess respiratory muscle function. This approach has gained attention as a potential tool to improve weaning outcomes and reduce extubation failure rates by providing more precise insights into respiratory muscle performance.AIM :The aim of this study was to propose a systematic ultrasound-based evaluation of the respiratory muscle pump compared with rapid shallow breathing index in ICU patients with prolonged mechanical ventilation.PATIENTS AND METHODSThis prospective observational study included 34 mechanically ventilated patients admitted to the Critical Care Medicine Department at Alexandria University Hospitals. Patients were intubated for over one week and met weaning readiness criteria. Respiratory muscle ultrasound was performed to measure diaphragmatic and parasternal intercostal muscle thickening fractions during spontaneous breathing trials (SBT). The RSBI was also calculated. Patients were categorized into successful (n=19) and failed (n=15) weaning groups based on extubation outcomes 48 hrs. post-extubation. Statistical analysis compared ultrasound parameters and RSBI in predicting weaning success, with a focus on sensitivity, specificity, and predictive accuracy.

Authors

Institutions

Publication Details

Journal
ALEXMED ePosters
Published
2025-04-01
DOI
https://doi.org/10.21608/alexpo.2025.380001.2154
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RESPIRATORY MUSCLE ULTRASOUND VERSUS RAPID SHALLOW BREATHING INDEX AS A WEANING PREDICTOR IN PROLONGED MECHANICALLY VENTILATED PATIENTS.

Mohammed Abd ElAlem, A Rahman, Akram Muhammad Fayed, Haitham Mohamed Tammam
ALEXMED ePosters
Respiratory Support and Mechanisms
article

RESPIRATORY MUSCLE ULTRASOUND VERSUS RAPID SHALLOW BREATHING INDEX AS A WEANING PREDICTOR IN PROLONGED MECHANICALLY VENTILATED PATIENTS.

Mohammed Abd ElAlem, A Rahman, Akram Muhammad Fayed, Haitham Mohamed Tammam
article en

Abstract

Mechanical ventilation is a life-saving intervention in intensive care units (ICUs), but prolonged use can lead to complications such as ventilator-induced diaphragmatic dysfunction (VIDD) and increased mortality. Weaning patients from mechanical ventilation is a critical process, with approximately 15% of patients requiring reintubation within 48 hours. Traditional weaning predictors, like the Rapid Shallow Breathing Index (RSBI), have limitations in accuracy. Respiratory muscle ultrasound, particularly diaphragmatic and parasternal intercostal muscle thickening fractions, offers a non-invasive, real-time method to assess respiratory muscle function. This approach has gained attention as a potential tool to improve weaning outcomes and reduce extubation failure rates by providing more precise insights into respiratory muscle performance.AIM :The aim of this study was to propose a systematic ultrasound-based evaluation of the respiratory muscle pump compared with rapid shallow breathing index in ICU patients with prolonged mechanical ventilation.PATIENTS AND METHODSThis prospective observational study included 34 mechanically ventilated patients admitted to the Critical Care Medicine Department at Alexandria University Hospitals. Patients were intubated for over one week and met weaning readiness criteria. Respiratory muscle ultrasound was performed to measure diaphragmatic and parasternal intercostal muscle thickening fractions during spontaneous breathing trials (SBT). The RSBI was also calculated. Patients were categorized into successful (n=19) and failed (n=15) weaning groups based on extubation outcomes 48 hrs. post-extubation. Statistical analysis compared ultrasound parameters and RSBI in predicting weaning success, with a focus on sensitivity, specificity, and predictive accuracy.

ALEXMED ePostersVol. 7(2)
Alexandria University (EG)
Openalex Percentile: Top 85%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.