Analysis on the clinical correlation of lens parameters and choroidal thickness with the severity of primary angle closure disease

<b>Purpose:</b> The purpose of this study is to investigate the correlation of lens parameters and choroidal thickness (RCS) with the severity of PACD and to compare those parameters with the normal population. <b>Methods:</b> Prospective, cross-sectional hospital-based study. A total of 286 subjects (572 eyes) including 236 study patients (472 eyes) and 50 age-matched controls (100 eyes) were included in the study. The parameters studied were anterior chamber depth (ACD), lens thickness (LT), anterior vault (AV), lens axial factor (LAF), lens position (LP), relative lens position (RLP), lens vault (LV) and RCS thickness. <b>Results:</b> The mean ACD was significantly shallow in all subtypes of Primary Angle Closure Glaucoma (PACG) (mean ± <i>SD</i> = 2.53 ± 0.34 mm) compared to controls (4.05 ± 0.16; <i>p</i> = 0.0001). Likewise, the mean lens thickness was more in all subtypes of PACD (mean ± <i>SD</i> = 4.67 ± 0.26 mm) than in normal controls (4.17 ± 0.17 mm; <i>p</i> = 0.0001). Moreover, PACD patients had higher LV (mean ± <i>SD</i> = 1174.29 ± 247.87) than in controls (778.23 ± 37.95; <i>p</i> = 0.0001), particularly in eyes with <b>AAC</b> (1328.86 ± 77.13). Other biometric parameters like AV, LAF, LP, RLP and RCS thickness revealed a statistically significant difference in PACD compared to the control population (<i>p</i> < 0.00001). Pairwise comparison also revealed significant difference in all ocular biometric parameters in <b>AAC</b> compared to other subtypes. <b>Conclusion:</b> Lens parameters and choroidal thickness correlated significantly with the severity of PACD. Our study highlights the interplay of multiple ocular biometric parameters with the disease severity, suggesting the individualised surgical options in patients with PACD.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2025-05-06
DOI
https://doi.org/10.1177/11206721251340230
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis on the clinical correlation of lens parameters and choroidal thickness with the severity of primary angle closure disease

Iswarya Mani, Niyati Pankaj Gandhi, Vijayalakshmi A Senthilkumar, Sayali Borikar et al.
European Journal of Ophthalmology
Glaucoma and retinal disorders
article

Analysis on the clinical correlation of lens parameters and choroidal thickness with the severity of primary angle closure disease

Iswarya Mani, Niyati Pankaj Gandhi, Vijayalakshmi A Senthilkumar, Sayali Borikar, Sharmila R Rajendrababu
article en

Abstract

<b>Purpose:</b> The purpose of this study is to investigate the correlation of lens parameters and choroidal thickness (RCS) with the severity of PACD and to compare those parameters with the normal population. <b>Methods:</b> Prospective, cross-sectional hospital-based study. A total of 286 subjects (572 eyes) including 236 study patients (472 eyes) and 50 age-matched controls (100 eyes) were included in the study. The parameters studied were anterior chamber depth (ACD), lens thickness (LT), anterior vault (AV), lens axial factor (LAF), lens position (LP), relative lens position (RLP), lens vault (LV) and RCS thickness. <b>Results:</b> The mean ACD was significantly shallow in all subtypes of Primary Angle Closure Glaucoma (PACG) (mean ± <i>SD</i> = 2.53 ± 0.34 mm) compared to controls (4.05 ± 0.16; <i>p</i> = 0.0001). Likewise, the mean lens thickness was more in all subtypes of PACD (mean ± <i>SD</i> = 4.67 ± 0.26 mm) than in normal controls (4.17 ± 0.17 mm; <i>p</i> = 0.0001). Moreover, PACD patients had higher LV (mean ± <i>SD</i> = 1174.29 ± 247.87) than in controls (778.23 ± 37.95; <i>p</i> = 0.0001), particularly in eyes with <b>AAC</b> (1328.86 ± 77.13). Other biometric parameters like AV, LAF, LP, RLP and RCS thickness revealed a statistically significant difference in PACD compared to the control population (<i>p</i> < 0.00001). Pairwise comparison also revealed significant difference in all ocular biometric parameters in <b>AAC</b> compared to other subtypes. <b>Conclusion:</b> Lens parameters and choroidal thickness correlated significantly with the severity of PACD. Our study highlights the interplay of multiple ocular biometric parameters with the disease severity, suggesting the individualised surgical options in patients with PACD.

European Journal of OphthalmologyVol. 35(6)
Aravind Eye Hospital (IN)
Openalex Percentile: Top 84%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis on the clinical correlation of lens parameters and choroidal thickness with the severity of primary angle closure disease — Iswarya Mani, Niyati Pankaj Gandhi, et al. · European Journal of Ophthalmology (2025) | TGRS Research Map | TGRS