Conventional mentality and new findings in plate glass (Part 1) — Stress relaxation phenomena and fracture —

Glass strength in plate glass was measured using the Quasi-static method to investigate its mechanical properties. New findings concerned with stress relaxation phenomena being generated at once after loading and time dependent fracture were seen even at room temperature. Load reduction phenomenon at room temperature has gone unnoticed for many years, because its value was 2–4.5 N in Caustics method, although measurement error approximately was 5 N in ordinary 4-point bending test method. Fracture in plate glass was inferred to be caused not only by applied stress to glass but also through complex behavior involving several factors. The concept of stress relaxation phenomenon under strain points that do not occur or occur over a lengthy period of several decades at least will be necessary to reconsider. Almina ceramics showed fracture characteristics closer to plate glass than silicon carbide which also called a ceramics.

Authors

Publication Details

Journal
Strength Fracture and Complexity
Published
2025-05-07
DOI
https://doi.org/10.1177/15672069251338116
Primary Topic
Structural Analysis of Composite Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conventional mentality and new findings in plate glass (Part 1) — Stress relaxation phenomena and fracture —

Shin’ichi ARATANI
Strength Fracture and Complexity
Structural Analysis of Composite Materials
article

Conventional mentality and new findings in plate glass (Part 1) — Stress relaxation phenomena and fracture —

Shin’ichi ARATANI
article en

Abstract

Glass strength in plate glass was measured using the Quasi-static method to investigate its mechanical properties. New findings concerned with stress relaxation phenomena being generated at once after loading and time dependent fracture were seen even at room temperature. Load reduction phenomenon at room temperature has gone unnoticed for many years, because its value was 2–4.5 N in Caustics method, although measurement error approximately was 5 N in ordinary 4-point bending test method. Fracture in plate glass was inferred to be caused not only by applied stress to glass but also through complex behavior involving several factors. The concept of stress relaxation phenomenon under strain points that do not occur or occur over a lengthy period of several decades at least will be necessary to reconsider. Almina ceramics showed fracture characteristics closer to plate glass than silicon carbide which also called a ceramics.

Strength Fracture and ComplexityVol. 19(1)
Openalex Percentile: Top 91%
Structural Analysis of Composite Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.