Spectrum, Prognostic Factors and Outcome of Commonly Missed Cause of Respiratory Distress in Children

Objectives Foreign body aspiration (FBA) is one of the important causes of respiratory distress, often missed. Early diagnosis and treatment prevent serious complications and improve the outcome. Our objective is to study the clinical profile, prognostic factors, and outcome of FBA in children. Material and Methods A prospective study was done from January 2019 to June 2023 in the Department of Paediatrics, Tertiary Care Centre, Tamil Nadu. Children aged 1 month–12 years presented with a history of FBA, and children brought with respiratory distress whose clinical-radiological findings favour FBA were included. Foreign body (FB) in the ear, nose, and gastrointestinal tract was excluded. Children’s age, sex, severity of hypoxia on arrival, duration between aspiration and diagnosis, duration of bronchoscopy procedure, site and nature of FB, pneumonia, and atelectasis in chest X-ray were the factors taken for analysis and outcome.Chi-square test and multiple logistic regression analysis were used for analysis. Results Totally 125 children were admitted with features of FBA. 32%, 52%, and 16% were in the age group of <1 year, 1–3 years, and >3 years respectively. 76% of children brought without a history of FBA came with complaints such as respiratory distress, recurrent respiratory tract infection, and wheezing. Decreased air entry on the one side of the chest was seen in 84% of children and chest X-ray showed same-side hyper-inflation in 72% of children. Computed tomography localized the FB in all cases. After a multiple logistic regression analysis, duration between Foreign body aspiration and diagnosis interval [odds ratio (OR) = 6.62, confidence interval (CI) = 1.22–35.8], duration of bronchoscopy procedure (OR = 3.6, CI = 1.65–7.89), pneumonia and atelectasis in chest X-ray (OR = 5.01, CI = 1.69–14.86) were associated with bad outcome. Conclusion A child presents with decreased air entry on one side of the chest and same side chest X ray showed hyperinflation, a FBA in the same main bronchus is the strong possibility. Early diagnosis and removal of FB yield excellent outcomes.

Authors

Publication Details

Journal
Annals of Child Health
Published
2025-05-07
DOI
https://doi.org/10.25259/ach_25_2024
Primary Topic
Foreign Body Medical Cases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectrum, Prognostic Factors and Outcome of Commonly Missed Cause of Respiratory Distress in Children

P Poovan, Ramya Balasubramanian, Narmatha Veerachamy, Sasikala Karuppannan et al.
Annals of Child Health
Foreign Body Medical Cases
article

Spectrum, Prognostic Factors and Outcome of Commonly Missed Cause of Respiratory Distress in Children

P Poovan, Ramya Balasubramanian, Narmatha Veerachamy, Sasikala Karuppannan, Balaji Jayaraman, Saranyadevi Chinnasamy
article en

Abstract

Objectives Foreign body aspiration (FBA) is one of the important causes of respiratory distress, often missed. Early diagnosis and treatment prevent serious complications and improve the outcome. Our objective is to study the clinical profile, prognostic factors, and outcome of FBA in children. Material and Methods A prospective study was done from January 2019 to June 2023 in the Department of Paediatrics, Tertiary Care Centre, Tamil Nadu. Children aged 1 month–12 years presented with a history of FBA, and children brought with respiratory distress whose clinical-radiological findings favour FBA were included. Foreign body (FB) in the ear, nose, and gastrointestinal tract was excluded. Children’s age, sex, severity of hypoxia on arrival, duration between aspiration and diagnosis, duration of bronchoscopy procedure, site and nature of FB, pneumonia, and atelectasis in chest X-ray were the factors taken for analysis and outcome.Chi-square test and multiple logistic regression analysis were used for analysis. Results Totally 125 children were admitted with features of FBA. 32%, 52%, and 16% were in the age group of <1 year, 1–3 years, and >3 years respectively. 76% of children brought without a history of FBA came with complaints such as respiratory distress, recurrent respiratory tract infection, and wheezing. Decreased air entry on the one side of the chest was seen in 84% of children and chest X-ray showed same-side hyper-inflation in 72% of children. Computed tomography localized the FB in all cases. After a multiple logistic regression analysis, duration between Foreign body aspiration and diagnosis interval [odds ratio (OR) = 6.62, confidence interval (CI) = 1.22–35.8], duration of bronchoscopy procedure (OR = 3.6, CI = 1.65–7.89), pneumonia and atelectasis in chest X-ray (OR = 5.01, CI = 1.69–14.86) were associated with bad outcome. Conclusion A child presents with decreased air entry on one side of the chest and same side chest X ray showed hyperinflation, a FBA in the same main bronchus is the strong possibility. Early diagnosis and removal of FB yield excellent outcomes.

Annals of Child HealthVol. 2
Openalex Percentile: Top 85%
Foreign Body Medical Cases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.