Luminescence Lifetime-Based Sensing of Water Turbidity

Current commercial turbidity sensors may be costly, bulky, or fragile. As such, many research groups have investigated alternative methods for the accurate determination of this essential water quality parameter. This work describes a new sensor based on luminescence measurements under a dual-lifetime reference scheme. By letting the turbid water pass between two dye layers with similar absorption and emission features but widely different emission lifetimes, an overall luminescence phase shift is measured, the magnitude of which depends on the turbidity. Dimethyl 2,5-bis(cyclohexylamino)terephthalate (BCT) is the reference fluorophore placed on the optical fiber tip after immobilization in a thin poly(vinyl chloride) (PVC) layer. The indicator luminophore, tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) (RD3), embedded into poly(ethyl 2-cyanoacrylate) (PCA), is separated from the reference layer by a user-selectable distance (1-2 cm). With increasing turbidity, the emission intensity of the indicator dye layer decreases, while the fluorescence intensity of the reference layer remains constant. In this way, the ratio between the two emission intensities is translated into changes in the lifetime (and phase shift) of the composite emission. The sensor's working range depends on the distance between the two dye layers. The sensor is capable of detecting turbidity levels in the range of 0-1000 NTU, 0-500 NTU, and 0-300 NTU for 1, 1.5, and 2 cm optical pathlengths, respectively, with an accuracy of 1 NTU (0.3 NTU between 0 and 10 NTU), limited by the accuracy of the turbidity standards. Shorter pathlengths allow the measurement of higher turbidity. The temperature-dependent response is instantaneous and devoid of dissolved O<sub>2</sub> and chlorophyll interferences. The sensor has been tested in a real-world environment for 11 days with good performance.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-05-07
DOI
https://doi.org/10.1021/acssensors.5c00849
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Luminescence Lifetime-Based Sensing of Water Turbidity

M. Darder, Guillermo Orellana, Ya Jie Knöbl, Iman Nakhli
ACS Sensors
Analytical Chemistry and Sensors
article

Luminescence Lifetime-Based Sensing of Water Turbidity

M. Darder, Guillermo Orellana, Ya Jie Knöbl, Iman Nakhli
article en

Abstract

Current commercial turbidity sensors may be costly, bulky, or fragile. As such, many research groups have investigated alternative methods for the accurate determination of this essential water quality parameter. This work describes a new sensor based on luminescence measurements under a dual-lifetime reference scheme. By letting the turbid water pass between two dye layers with similar absorption and emission features but widely different emission lifetimes, an overall luminescence phase shift is measured, the magnitude of which depends on the turbidity. Dimethyl 2,5-bis(cyclohexylamino)terephthalate (BCT) is the reference fluorophore placed on the optical fiber tip after immobilization in a thin poly(vinyl chloride) (PVC) layer. The indicator luminophore, tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) (RD3), embedded into poly(ethyl 2-cyanoacrylate) (PCA), is separated from the reference layer by a user-selectable distance (1-2 cm). With increasing turbidity, the emission intensity of the indicator dye layer decreases, while the fluorescence intensity of the reference layer remains constant. In this way, the ratio between the two emission intensities is translated into changes in the lifetime (and phase shift) of the composite emission. The sensor's working range depends on the distance between the two dye layers. The sensor is capable of detecting turbidity levels in the range of 0-1000 NTU, 0-500 NTU, and 0-300 NTU for 1, 1.5, and 2 cm optical pathlengths, respectively, with an accuracy of 1 NTU (0.3 NTU between 0 and 10 NTU), limited by the accuracy of the turbidity standards. Shorter pathlengths allow the measurement of higher turbidity. The temperature-dependent response is instantaneous and devoid of dissolved O<sub>2</sub> and chlorophyll interferences. The sensor has been tested in a real-world environment for 11 days with good performance.

ACS SensorsVol. 10(5)
Universidad Complutense de Madrid (ES)
Universidad Complutense de Madrid
Clean water and sanitation
Openalex Percentile: Top 87%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.