Validity of Hera Leto consumer earbuds for heart rate monitoring during stationary cycling

Heart rate (HR) monitoring using earbuds presents a promising avenue for precise measurement, yet its validity remains under investigation during stationary cycling. In this study, we assessed the validity of the Hera Leto consumer earbuds by enrolling twenty-eight athletes as participants. Each participant wore a chest-strap Polar H10, considered the gold-standard reference, while simultaneously testing three HR monitors: the Hera Leto (worn on the ears), the Polar Verity Sense (worn on the upper arm), and the Polar Vantage V (worn on the wrist). The exercise protocol included four steady-state exercise sessions, six sessions of severe intensity exhaustive exercise, and three high-intensity interval training (HIIT) sessions. Our findings revealed a robust correlation ([Formula: see text]=0.970, [Formula: see text]<0.001) between the HR measurements obtained from Hera Leto and Polar H10 across all exercise intensities, with a minimal systematic bias of - 0.67 bpm. with a minimal systematic bias of -0.67 bpm. Notably, Hera Leto demonstrated superior performance, with a mean absolute error (MAE) of 2 bpm and concordance correlation coefficient (CCC) of 0.97, compared to the Polar Verity Sense (MAE = 4 bpm, CCC = 0.88) and Polar Vantage V (MAE = 4 bpm, CCC = 0.93). Although the precision of HR measurement decreased with increasing exercise intensity, Hera Leto exhibited a slower onset of this decline compared to the other devices. Overall, our study underscores the potential of Hera Leto earbuds as a valid tool for HR monitoring, particularly in scenarios involving steady-state exercise.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-07
DOI
https://doi.org/10.1038/s41598-025-00559-5
Citations
3
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
4.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validity of Hera Leto consumer earbuds for heart rate monitoring during stationary cycling

Junqiang Qiu, Kuan Tao, Junchao Yang, Xiangxin Li et al.
3 citations
Scientific Reports
Heart Rate Variability and Autonomic Control
4.16
article

Validity of Hera Leto consumer earbuds for heart rate monitoring during stationary cycling

Junqiang Qiu, Kuan Tao, Junchao Yang, Xiangxin Li, LU Zhi-hui
article en
3 citations

Abstract

Heart rate (HR) monitoring using earbuds presents a promising avenue for precise measurement, yet its validity remains under investigation during stationary cycling. In this study, we assessed the validity of the Hera Leto consumer earbuds by enrolling twenty-eight athletes as participants. Each participant wore a chest-strap Polar H10, considered the gold-standard reference, while simultaneously testing three HR monitors: the Hera Leto (worn on the ears), the Polar Verity Sense (worn on the upper arm), and the Polar Vantage V (worn on the wrist). The exercise protocol included four steady-state exercise sessions, six sessions of severe intensity exhaustive exercise, and three high-intensity interval training (HIIT) sessions. Our findings revealed a robust correlation ([Formula: see text]=0.970, [Formula: see text]<0.001) between the HR measurements obtained from Hera Leto and Polar H10 across all exercise intensities, with a minimal systematic bias of - 0.67 bpm. with a minimal systematic bias of -0.67 bpm. Notably, Hera Leto demonstrated superior performance, with a mean absolute error (MAE) of 2 bpm and concordance correlation coefficient (CCC) of 0.97, compared to the Polar Verity Sense (MAE = 4 bpm, CCC = 0.88) and Polar Vantage V (MAE = 4 bpm, CCC = 0.93). Although the precision of HR measurement decreased with increasing exercise intensity, Hera Leto exhibited a slower onset of this decline compared to the other devices. Overall, our study underscores the potential of Hera Leto earbuds as a valid tool for HR monitoring, particularly in scenarios involving steady-state exercise.

Scientific ReportsVol. 15(1)
Beijing Sport University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 6%
Heart Rate Variability and Autonomic Control
4.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validity of Hera Leto consumer earbuds for heart rate monitoring during stationary cycling — Junqiang Qiu, Kuan Tao, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS