Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique

Objective: This study aimed to compare the biomechanical characteristics of conventional transosseous equivalent (TOE) techniques with those of the novel free independent double-row medial fixation method, using rigid polyurethane (PU) foam blocks to simulate osteoporotic humerus bone. Methods: In this biomechanical study, 4 groups were tested using rigid PU foam blocks with osteoporotic properties and bovine infraspinatus tendons to simulate the rotator cuff. Groups 1 and 2 employed conventional TOE techniques: medial row knotted repair and knotless repair, respectively. Groups 3 and 4 utilized the "free independent double-row medial fixation method," differing in the order of suture tying. Several biomechanical characteristic and pressure parameters were measured. Results: Groups 3 (0.16 ± 0.04 MPa) and 4 (0.17 ± 0.05 MPa) achieved significantly higher initial contact pressure compared to standard TOE techniques (P=.039). While contact area (Group 3: 102.4 ± 55.0 mm², Group 4: 110.4 ± 37.2 mm²) and ultimate failure force (Group 3: 212.0 ± 26.5 N, Group 4: 214.7 ± 30.2 N) were relatively higher, the differences were not statistically significant (P=.135 and P=.3, respectively). The overall failure types included medial anchor pullout (40%) and suture/tendon stripping (32.5%), with no significant differences among groups (P=.260). Conclusion: With superior contact pressure and comparable ultimate failure and contact area measurements, the novel independent double-row medial fixation technique may be a viable alternative to conventional TOE techniques for enhancing medial row stability in osteoporotic conditions. Level of Evidence: N/A.

Authors

Institutions

Publication Details

Journal
Acta Orthopaedica et Traumatologica Turcica
Published
2025-04-29
DOI
https://doi.org/10.5152/j.aott.2025.24077
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique

Yunus İmren, Yaşar Tatar, Süleyman Semih Dedeoğlu, Nejla Gerçek et al.
Acta Orthopaedica et Traumatologica Turcica
Shoulder Injury and Treatment
article

Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique

Yunus İmren, Yaşar Tatar, Süleyman Semih Dedeoğlu, Nejla Gerçek, Ahmet Keskin, Hakan Eskara
article en

Abstract

Objective: This study aimed to compare the biomechanical characteristics of conventional transosseous equivalent (TOE) techniques with those of the novel free independent double-row medial fixation method, using rigid polyurethane (PU) foam blocks to simulate osteoporotic humerus bone. Methods: In this biomechanical study, 4 groups were tested using rigid PU foam blocks with osteoporotic properties and bovine infraspinatus tendons to simulate the rotator cuff. Groups 1 and 2 employed conventional TOE techniques: medial row knotted repair and knotless repair, respectively. Groups 3 and 4 utilized the "free independent double-row medial fixation method," differing in the order of suture tying. Several biomechanical characteristic and pressure parameters were measured. Results: Groups 3 (0.16 ± 0.04 MPa) and 4 (0.17 ± 0.05 MPa) achieved significantly higher initial contact pressure compared to standard TOE techniques (P=.039). While contact area (Group 3: 102.4 ± 55.0 mm², Group 4: 110.4 ± 37.2 mm²) and ultimate failure force (Group 3: 212.0 ± 26.5 N, Group 4: 214.7 ± 30.2 N) were relatively higher, the differences were not statistically significant (P=.135 and P=.3, respectively). The overall failure types included medial anchor pullout (40%) and suture/tendon stripping (32.5%), with no significant differences among groups (P=.260). Conclusion: With superior contact pressure and comparable ultimate failure and contact area measurements, the novel independent double-row medial fixation technique may be a viable alternative to conventional TOE techniques for enhancing medial row stability in osteoporotic conditions. Level of Evidence: N/A.

Acta Orthopaedica et Traumatologica TurcicaVol. 59(2)
Baltalimanı Kemik Hastalıkları Hastanesi (TR), Education Training And Research (US), Liv Hospital (TR), Marmara University (TR)
Openalex Percentile: Top 83%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.