Refillable Intraocular Drug-Eluting Implant

The increasing incidence of ophthalmic diseases has led the need for multiple dosage regimens, which can cause patient discomfort and noncompliance due to the frequency of medication administration. Still, ophthalmic drug delivery methods, such as eye drops and intravitreal injection, pose challenges, such as poor bioavailability, short half-life, and patient compliance. In this study, we introduce a novel refillable intracapsular drug-eluting reservoir for the long-term management of ocular diseases. This device, made of medical-grade silicone and stainless steel, has features to contour the lens capsule to facilitate microincisional implantation. Rheological and mechanical analyses of the silicone revealed the optimized conditions for the device construction and its application compliance for ocular intracapsular implantation. Furthermore, in vitro release studies exhibit controlled drug release, the kinetics of which were along with Fickian diffusion, while ex vivo implantation testing shows that the device can be easily delivered and placed at the time of cataract surgery. Taken altogether, the developed implant holds significant potential for improving therapeutic outcomes while offering a practical surgical application and compliance of patients.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-05-07
DOI
https://doi.org/10.1021/acsami.5c03985
Citations
2
Primary Topic
Retinal Development and Disorders
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Refillable Intraocular Drug-Eluting Implant

Robert A. Wise, David Myung, Charles DeBoer, Hyeonji Kim et al.
2 citations
ACS Applied Materials & Interfaces
Retinal Development and Disorders
1.61
article

Refillable Intraocular Drug-Eluting Implant

Robert A. Wise, David Myung, Charles DeBoer, Hyeonji Kim, Nae-Won Kang, Akira Feliz
article en
2 citations

Abstract

The increasing incidence of ophthalmic diseases has led the need for multiple dosage regimens, which can cause patient discomfort and noncompliance due to the frequency of medication administration. Still, ophthalmic drug delivery methods, such as eye drops and intravitreal injection, pose challenges, such as poor bioavailability, short half-life, and patient compliance. In this study, we introduce a novel refillable intracapsular drug-eluting reservoir for the long-term management of ocular diseases. This device, made of medical-grade silicone and stainless steel, has features to contour the lens capsule to facilitate microincisional implantation. Rheological and mechanical analyses of the silicone revealed the optimized conditions for the device construction and its application compliance for ocular intracapsular implantation. Furthermore, in vitro release studies exhibit controlled drug release, the kinetics of which were along with Fickian diffusion, while ex vivo implantation testing shows that the device can be easily delivered and placed at the time of cataract surgery. Taken altogether, the developed implant holds significant potential for improving therapeutic outcomes while offering a practical surgical application and compliance of patients.

ACS Applied Materials & InterfacesVol. 17(23)
VA Palo Alto Health Care System (US), Charles R. Drew University of Medicine and Science (US), Smith-Kettlewell Eye Research Institute (US), Stanford University (US)
Research to Prevent Blindness, E. Matilda Ziegler Foundation for the Blind, National Institutes of Health, Alcon Research Institute
Openalex Percentile: Top 17%
Retinal Development and Disorders
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Refillable Intraocular Drug-Eluting Implant — Robert A. Wise, David Myung, et al. · ACS Applied Materials & Interfaces (2025) | TGRS Research Map | TGRS