Impact of external radiation on dark rate noise measurement for the Hyper-Kamiokande photomultiplier tube

Abstract The Hyper-Kamiokande (HK) is a next-generation water Cherenkov detector currently under construction in Japan as of 2025, and scheduled to begin operation in 2027. A new PMT has been developed for HK with improvements in detection efficiency, timing resolution, and pressure tolerance by a factor of two with respect to those used in the Super-Kamiokande detector. The HK detector will be instrumented with 20,000 photomultiplier tubes (PMT). Currently, the PMTs are produced, and the performance testing of the delivered PMTs is underway in parallel. In this test, it was observed that the dark rate values differed depending on the measurement location. The difference is considered due to environmental radiation, and we have conducted measurements of dark rate variations with radiation sources. We measured correlations between the irradiation of γ rays and dark noise rate and the evaluated intrinsic dark noise rate of HK PMT after subtracting the contribution due to environmental radiation.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-05-01
DOI
https://doi.org/10.1088/1748-0221/20/05/c05011
Primary Topic
Astrophysics and Cosmic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of external radiation on dark rate noise measurement for the Hyper-Kamiokande photomultiplier tube

T. Tashiro, C. Bronner, Y. Nishimura, M. Ishitsuka et al.
Journal of Instrumentation
Astrophysics and Cosmic Phenomena
article

Impact of external radiation on dark rate noise measurement for the Hyper-Kamiokande photomultiplier tube

T. Tashiro, C. Bronner, Y. Nishimura, M. Ishitsuka, Y Mandokoro
article en

Abstract

Abstract The Hyper-Kamiokande (HK) is a next-generation water Cherenkov detector currently under construction in Japan as of 2025, and scheduled to begin operation in 2027. A new PMT has been developed for HK with improvements in detection efficiency, timing resolution, and pressure tolerance by a factor of two with respect to those used in the Super-Kamiokande detector. The HK detector will be instrumented with 20,000 photomultiplier tubes (PMT). Currently, the PMTs are produced, and the performance testing of the delivered PMTs is underway in parallel. In this test, it was observed that the dark rate values differed depending on the measurement location. The difference is considered due to environmental radiation, and we have conducted measurements of dark rate variations with radiation sources. We measured correlations between the irradiation of γ rays and dark noise rate and the evaluated intrinsic dark noise rate of HK PMT after subtracting the contribution due to environmental radiation.

Journal of InstrumentationVol. 20(05)
Nakanihon Automotive College (JP), Tokyo University of Science (JP), Keio University (JP), Jikei University Kashiwa hospital (JP)
Openalex Percentile: Top 95%
Astrophysics and Cosmic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.