Modeling and Optimization of Nonlinear Viscoelastic Behavior for Tissue-Engineered Blood Vessels

Vascular tissue engineering technology uses tubular viscoelastic materials as intermediaries to transmit the mechanical stimuli required for the construction of vascular grafts. However, most existing studies rely on elastic models, which fail to capture the time-dependent nature of viscoelastic materials. Moreover, the long fabrication cycles, high costs, and complex parameter measurements in tissue engineering pose significant challenges to experimental approaches. There is thus an urgent need to develop a viscoelastic mechanical model that combines physical interpretability, computational efficiency, and predictive accuracy, enabling precise characterization of material responses and unified quantification across experimental platforms. Here, we propose an error-corrected linear solid (ECLS) model with an embedded correction term to address the predictive deviations of conventional models in nonlinear viscoelastic scenarios. Instead of expanding the traditional model structure, the ECLS incorporates an error correction method that improves predictive performance while maintaining structural simplicity. Experiments were conducted on three representative viscoelastic materials-silicone rubber, polyurethane, and polytetrafluoroethylene-to acquire time-resolved response data through stress relaxation and creep tests. The fitting performance was quantitatively evaluated using the Euclidean norm and the Akaike information criterion, enabling a systematic comparison between the ECLS model and three classical models (Kelvin-Voigt, Maxwell, and standard linear solid [SLS]). The results show that the ECLS model exhibits higher predictive accuracy over a wide time range, with an average goodness of fit (R<sup>2</sup>) of 0.99, representing an improvement of ∼6% compared to the SLS model. Furthermore, the Root Mean Square Error (RMSE) and Mean Absolute Error (MAE) of the ECLS model are at least one order of magnitude lower than those of the traditional models, significantly improving the description of nonlinear viscoelastic behavior and providing more accurate predictions of material viscoelastic mechanical behavior. Therefore, the ECLS model not only improves the modeling accuracy of viscoelastic behavior but also establishes a unified and scalable framework for predicting and optimizing the mechanical performance of tissue-engineered vessels, expanding the application potential of mechanical modeling in bioreactor design and biomaterials development.

Authors

Institutions

Publication Details

Journal
Tissue Engineering Part C Methods
Published
2025-05-01
DOI
https://doi.org/10.1089/ten.tec.2025.0039
Citations
2
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
1.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling and Optimization of Nonlinear Viscoelastic Behavior for Tissue-Engineered Blood Vessels

Zhanyi Lin, Haohao Zhou, Wenjing Luo, Wanwen Chen et al.
2 citations
Tissue Engineering Part C Methods
Electrospun Nanofibers in Biomedical Applications
1.19
article

Modeling and Optimization of Nonlinear Viscoelastic Behavior for Tissue-Engineered Blood Vessels

Zhanyi Lin, Haohao Zhou, Wenjing Luo, Wanwen Chen, Jierong Liang, Jiandong Li, Xuheng Sun, Jing Yang, Jianming Cai
article en
2 citations

Abstract

Vascular tissue engineering technology uses tubular viscoelastic materials as intermediaries to transmit the mechanical stimuli required for the construction of vascular grafts. However, most existing studies rely on elastic models, which fail to capture the time-dependent nature of viscoelastic materials. Moreover, the long fabrication cycles, high costs, and complex parameter measurements in tissue engineering pose significant challenges to experimental approaches. There is thus an urgent need to develop a viscoelastic mechanical model that combines physical interpretability, computational efficiency, and predictive accuracy, enabling precise characterization of material responses and unified quantification across experimental platforms. Here, we propose an error-corrected linear solid (ECLS) model with an embedded correction term to address the predictive deviations of conventional models in nonlinear viscoelastic scenarios. Instead of expanding the traditional model structure, the ECLS incorporates an error correction method that improves predictive performance while maintaining structural simplicity. Experiments were conducted on three representative viscoelastic materials-silicone rubber, polyurethane, and polytetrafluoroethylene-to acquire time-resolved response data through stress relaxation and creep tests. The fitting performance was quantitatively evaluated using the Euclidean norm and the Akaike information criterion, enabling a systematic comparison between the ECLS model and three classical models (Kelvin-Voigt, Maxwell, and standard linear solid [SLS]). The results show that the ECLS model exhibits higher predictive accuracy over a wide time range, with an average goodness of fit (R<sup>2</sup>) of 0.99, representing an improvement of ∼6% compared to the SLS model. Furthermore, the Root Mean Square Error (RMSE) and Mean Absolute Error (MAE) of the ECLS model are at least one order of magnitude lower than those of the traditional models, significantly improving the description of nonlinear viscoelastic behavior and providing more accurate predictions of material viscoelastic mechanical behavior. Therefore, the ECLS model not only improves the modeling accuracy of viscoelastic behavior but also establishes a unified and scalable framework for predicting and optimizing the mechanical performance of tissue-engineered vessels, expanding the application potential of mechanical modeling in bioreactor design and biomaterials development.

Tissue Engineering Part C MethodsVol. 31(5)
Ji Hua Laboratory (CN), Guangdong Academy of Medical Sciences (CN), Guangdong Provincial People's Hospital (CN), South China University of Technology (CN)
Openalex Percentile: Top 23%
Electrospun Nanofibers in Biomedical Applications
1.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines