IBIC analysis of a linear position sensitive detector: model and experiment

Abstract The ion beam-induced charge (IBIC) analysis of a commercial silicon photodiode configured as a position sensitive detector (PSD) for energetic charged particles is the subject of this report. Although the photodiode is designed for detecting the position of incident light and optimized for use in the UV region, we present evidence that it also performs well as a detector for ions, with energies in the MeV range. The device consists of a uniform p -type layer formed on a high-resistivity n -type semiconductor substrate, a pair of electrodes on both ends of the resistive layer, and a common electrode located on the backside of the substrate. The IBIC experiment was carried out at the Laboratory for Ion Beam Interaction of the Ruder Boskovic Institute in Zagreb (HR), using 2 MeV proton microbeam raster scanning the (2.5 mm × 0.6 mm) active area of the PSD. Each of the three electrodes was connected to independent standard NIM charge-sensitive electronic chain and the induced charge pulses associated with the position of individual ions were then digitized using a multi-channel analyzer interfaced with the SPECTOR software. The longitudinal charge collection efficiency profiles acquired from the top electrodes show linear behaviors with opposite slopes, whereas the profile relevant to the signals from the back electrode is almost constant. A model based on the IBIC theory satisfactorily interprets these results. It offers an alternative viewpoint to the commonly adopted Lateral Effect Photodiode principle and paves the way for the development of new PSDs for the identification of the impact position of a MeV ion with a resolution at the micrometer scale.

Authors

Institutions

Publication Details

Journal
The European Physical Journal Plus
Published
2025-05-07
DOI
https://doi.org/10.1140/epjp/s13360-025-06291-3
Citations
2
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
3.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IBIC analysis of a linear position sensitive detector: model and experiment

M. Jakšić, E. Vittone, G. Provatas, Karla Ivanković Nizić
2 citations
The European Physical Journal Plus
Particle Detector Development and Performance
3.74
article

IBIC analysis of a linear position sensitive detector: model and experiment

M. Jakšić, E. Vittone, G. Provatas, Karla Ivanković Nizić
article en
2 citations

Abstract

Abstract The ion beam-induced charge (IBIC) analysis of a commercial silicon photodiode configured as a position sensitive detector (PSD) for energetic charged particles is the subject of this report. Although the photodiode is designed for detecting the position of incident light and optimized for use in the UV region, we present evidence that it also performs well as a detector for ions, with energies in the MeV range. The device consists of a uniform p -type layer formed on a high-resistivity n -type semiconductor substrate, a pair of electrodes on both ends of the resistive layer, and a common electrode located on the backside of the substrate. The IBIC experiment was carried out at the Laboratory for Ion Beam Interaction of the Ruder Boskovic Institute in Zagreb (HR), using 2 MeV proton microbeam raster scanning the (2.5 mm × 0.6 mm) active area of the PSD. Each of the three electrodes was connected to independent standard NIM charge-sensitive electronic chain and the induced charge pulses associated with the position of individual ions were then digitized using a multi-channel analyzer interfaced with the SPECTOR software. The longitudinal charge collection efficiency profiles acquired from the top electrodes show linear behaviors with opposite slopes, whereas the profile relevant to the signals from the back electrode is almost constant. A model based on the IBIC theory satisfactorily interprets these results. It offers an alternative viewpoint to the commonly adopted Lateral Effect Photodiode principle and paves the way for the development of new PSDs for the identification of the impact position of a MeV ion with a resolution at the micrometer scale.

The European Physical Journal PlusVol. 140(5)
Ruđer Bošković Institute (HR), Torino e-district (IT), University of Turin (IT)
European Commission, Università degli Studi di Torino, HORIZON EUROPE Framework Programme, HORIZON EUROPE European Innovation Council
Openalex Percentile: Top 8%
Particle Detector Development and Performance
3.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.