Heat Transfer Characteristics of Novel Resin Impregnated Paper Converter Transformer Valve‐Side Bushing With Two‐Phase Closed Thermosyphon

ABSTRACT Resin impregnated paper (RIP) converter transformer valve‐side bushings are the key equipment in converter stations. Local overheating of the RIP core not only reduces the transmission efficiency but also causes insulation failure of converter transformers. In this paper, a new heat dissipation structure is proposed to improve the temperature distribution homogeneity of the bushing using two‐phase closed thermosyphon (TPCT). A test model is developed to determine the optimal working fluid inventory. Then, the temperature distribution of a ± 400‐kV RIP converter transformer valve‐side bushing with an optimised heat dissipation structure is obtained using the coupled three‐dimensional electromagnetic‐fluid‐thermal numerical simulation method considering multiphase flow and phase change processes. The influence of the new structure on the electric field is analysed. The simulation result is verified by the temperature rise test. The results show that two‐phase closed thermosyphon can reduce the maximum temperature of the RIP valve‐side bushings and significantly improve the temperature distribution homogeneity.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2025-05-07
DOI
https://doi.org/10.1049/hve2.70011
Citations
1
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat Transfer Characteristics of Novel Resin Impregnated Paper Converter Transformer Valve‐Side Bushing With Two‐Phase Closed Thermosyphon

Zishi Yang, Peng Liu, Zuoming Xu, Qingyu Wang et al.
1 citations
High Voltage
Thermal Analysis in Power Transmission
1.21
article

Heat Transfer Characteristics of Novel Resin Impregnated Paper Converter Transformer Valve‐Side Bushing With Two‐Phase Closed Thermosyphon

Zishi Yang, Peng Liu, Zuoming Xu, Qingyu Wang, Zongren Peng, Wei Hu
article en
1 citations

Abstract

ABSTRACT Resin impregnated paper (RIP) converter transformer valve‐side bushings are the key equipment in converter stations. Local overheating of the RIP core not only reduces the transmission efficiency but also causes insulation failure of converter transformers. In this paper, a new heat dissipation structure is proposed to improve the temperature distribution homogeneity of the bushing using two‐phase closed thermosyphon (TPCT). A test model is developed to determine the optimal working fluid inventory. Then, the temperature distribution of a ± 400‐kV RIP converter transformer valve‐side bushing with an optimised heat dissipation structure is obtained using the coupled three‐dimensional electromagnetic‐fluid‐thermal numerical simulation method considering multiphase flow and phase change processes. The influence of the new structure on the electric field is analysed. The simulation result is verified by the temperature rise test. The results show that two‐phase closed thermosyphon can reduce the maximum temperature of the RIP valve‐side bushings and significantly improve the temperature distribution homogeneity.

High VoltageVol. 10(5)
China Electric Power Research Institute, Xi'an Jiaotong University (CN)
State Grid Corporation of China, Science and Technology Project of State Grid
Openalex Percentile: Top 22%
Thermal Analysis in Power Transmission
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.