Analysis and reflection on relay protection rejection accident of an offshore wind farm

The relay protection device is an automatic device that can detect the fault in the power system and carry out the operation, which is an important guarantee to ensure the safe and stable operation in the power system. If the protection devices misoperates or rejection, it will cause unnecessary offline and even expand the fault range. The paper discusses the common reasons for misoperates and rejection, and describes two large-scale wind turbine offline accidents caused by zero-sequence over-current protection rejection in an offshore wind farm. The main reason for the accident is that the setting of the over-current protection device is wrong. The actual grounding impedance of the ground transformer is much larger than the design value, resulting in the actual zero-sequence fault current less than the setting value of the protection, so the protection refuses to operate. At last, the paper gives some suggestions to avoid such accident, such as strengthen the maintenance and adjusting the protection setting value.

Authors

Institutions

Publication Details

Published
2025-05-07
DOI
https://doi.org/10.1117/12.3060570
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and reflection on relay protection rejection accident of an offshore wind farm

Bowen Ni, Le Zhang, Pengyu Li, Peng Huo
Power Systems Fault Detection
article

Analysis and reflection on relay protection rejection accident of an offshore wind farm

Bowen Ni, Le Zhang, Pengyu Li, Peng Huo
article en

Abstract

The relay protection device is an automatic device that can detect the fault in the power system and carry out the operation, which is an important guarantee to ensure the safe and stable operation in the power system. If the protection devices misoperates or rejection, it will cause unnecessary offline and even expand the fault range. The paper discusses the common reasons for misoperates and rejection, and describes two large-scale wind turbine offline accidents caused by zero-sequence over-current protection rejection in an offshore wind farm. The main reason for the accident is that the setting of the over-current protection device is wrong. The actual grounding impedance of the ground transformer is much larger than the design value, resulting in the actual zero-sequence fault current less than the setting value of the protection, so the protection refuses to operate. At last, the paper gives some suggestions to avoid such accident, such as strengthen the maintenance and adjusting the protection setting value.

Qinghai New Energy (China) (CN), Ningxia Normal University (CN), Ningxia Water Conservancy (CN)
Affordable and clean energy
Openalex Percentile: Top 90%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis and reflection on relay protection rejection accident of an offshore wind farm — Bowen Ni, Le Zhang, et al. · (2025) | TGRS Research Map | TGRS