A Comparative Study on the Shielding Calculation Methods for an Optimal Shielding Design of Isolation Rooms in a Nuclear Medicine Facility in the Philippines Providing 131I Thyroid Ablation Therapy

Iodine-131 ( 131 I) has been used widely in diagnosing and treating thyroid disorders, but its radioactive nature poses risks of gamma radiation exposure to those near the patient. To mitigate this, radiation protection measures are needed, among which is the provision of optimal structural shielding. In the Philippines, achieving this involves using minimum shielding thickness to meet safety limits from national regulations. Widely used conventional methods, like those based on the tenth-value layer (TVLs) measurements, may yield poor estimates, while computational simulations are precise but impractical to use due to their complexity. Archer's fitting method offers a simple and accurate alternative for designing optimal shielding in medical imaging and radiotherapy facilities based on multiple studies. However, little to no data is available regarding the use of Archer's fitting method in providing better accuracy in shielding calculations in isolation rooms of 131 I therapy facilities. A comparison of the transmission factors calculated using different calculation methods was done, and their effect on the minimum shielding thicknesses was investigated. Transmission curves generated with broad-beam TVLs reported from previous studies yielded the closest agreement with ANS/ANSI 6.4.3 buildup factors for lead barriers. On the other hand, results showed the closest agreement among the transmission curves and shielding thicknesses acquired with the American National Standard (ANSI/ANS) 6.4.3. buildup factors, Archer's fitting method, and Monte Carlo simulation through Particle Heavy Ion Transport System (PHITS) ver. 3.28 code for ordinary concrete barriers. Poor agreement was seen with the curves generated with the Narrow-Beam and Ideal Broad Beam TVL methods and the curve generated with ANSI/ANS 6.4.3. buildup factor data. Broad-Beam TVLs from previous studies, Monte Carlo Simulation, and Archer's fit can be alternative options for shielding design. An experimental study is proposed for verification.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2025-05-07
DOI
https://doi.org/10.1097/hp.0000000000001988
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Study on the Shielding Calculation Methods for an Optimal Shielding Design of Isolation Rooms in a Nuclear Medicine Facility in the Philippines Providing 131I Thyroid Ablation Therapy

Vangeline K. Parami, Javier Gonzales, K.M. Romallosa-Dean, M.E.S.K.V. Ramo
Health Physics
Radiation Dose and Imaging
article

A Comparative Study on the Shielding Calculation Methods for an Optimal Shielding Design of Isolation Rooms in a Nuclear Medicine Facility in the Philippines Providing 131I Thyroid Ablation Therapy

Vangeline K. Parami, Javier Gonzales, K.M. Romallosa-Dean, M.E.S.K.V. Ramo
article en

Abstract

Iodine-131 ( 131 I) has been used widely in diagnosing and treating thyroid disorders, but its radioactive nature poses risks of gamma radiation exposure to those near the patient. To mitigate this, radiation protection measures are needed, among which is the provision of optimal structural shielding. In the Philippines, achieving this involves using minimum shielding thickness to meet safety limits from national regulations. Widely used conventional methods, like those based on the tenth-value layer (TVLs) measurements, may yield poor estimates, while computational simulations are precise but impractical to use due to their complexity. Archer's fitting method offers a simple and accurate alternative for designing optimal shielding in medical imaging and radiotherapy facilities based on multiple studies. However, little to no data is available regarding the use of Archer's fitting method in providing better accuracy in shielding calculations in isolation rooms of 131 I therapy facilities. A comparison of the transmission factors calculated using different calculation methods was done, and their effect on the minimum shielding thicknesses was investigated. Transmission curves generated with broad-beam TVLs reported from previous studies yielded the closest agreement with ANS/ANSI 6.4.3 buildup factors for lead barriers. On the other hand, results showed the closest agreement among the transmission curves and shielding thicknesses acquired with the American National Standard (ANSI/ANS) 6.4.3. buildup factors, Archer's fitting method, and Monte Carlo simulation through Particle Heavy Ion Transport System (PHITS) ver. 3.28 code for ordinary concrete barriers. Poor agreement was seen with the curves generated with the Narrow-Beam and Ideal Broad Beam TVL methods and the curve generated with ANSI/ANS 6.4.3. buildup factor data. Broad-Beam TVLs from previous studies, Monte Carlo Simulation, and Archer's fit can be alternative options for shielding design. An experimental study is proposed for verification.

Health PhysicsVol. 129(6)
Philippine Medical Association (PH), University of Santo Tomas (PH), University of the Philippines Diliman (PH)
Openalex Percentile: Top 85%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.