Numerical simulation analysis of hydraulic transient process of hydropower station based on field test

Taking No.1 hydroelectric generating unit of Gongzui Hydropower Station after technical modification as the research object, and taking the load rejection test data of it as the reference, numerical simulation inversion is carried out by adopting the method of characteristics in order to modify the simulation model. On this basis, a numerical simulation analysis was carried out for No.1 unit at typical operating conditions of load dumping to determine a more appropriate equivalent closing time of the gate servomotor (<i>T<sub>f</sub></i>). The results show that the <i>T<sub>f</sub></i> (hydrostatic condition) should be adjusted to 8.7 s. When the water level of the upstream reservoir is at the normal storage level and the rated load is dumped at the maximum head, the inlet pressure of the spiral case (<i>P<sub>s</sub></i>) is not more than 0.838 MPa. Meanwhile, the frequency of the unit (<i>f</i>) is not more than 71 Hz, when dumping loads at rated operating conditions.

Authors

Institutions

Publication Details

Published
2025-05-07
DOI
https://doi.org/10.1117/12.3060467
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical simulation analysis of hydraulic transient process of hydropower station based on field test

Qin Zhang, Lu Zhang, Shan Yu, Xutao Yi et al.
Hydraulic and Pneumatic Systems
article

Numerical simulation analysis of hydraulic transient process of hydropower station based on field test

Qin Zhang, Lu Zhang, Shan Yu, Xutao Yi, Zhengzheng Chu, Youquan Zheng, Fuqin Xiong
article en

Abstract

Taking No.1 hydroelectric generating unit of Gongzui Hydropower Station after technical modification as the research object, and taking the load rejection test data of it as the reference, numerical simulation inversion is carried out by adopting the method of characteristics in order to modify the simulation model. On this basis, a numerical simulation analysis was carried out for No.1 unit at typical operating conditions of load dumping to determine a more appropriate equivalent closing time of the gate servomotor (<i>T<sub>f</sub></i>). The results show that the <i>T<sub>f</sub></i> (hydrostatic condition) should be adjusted to 8.7 s. When the water level of the upstream reservoir is at the normal storage level and the rated load is dumped at the maximum head, the inlet pressure of the spiral case (<i>P<sub>s</sub></i>) is not more than 0.838 MPa. Meanwhile, the frequency of the unit (<i>f</i>) is not more than 71 Hz, when dumping loads at rated operating conditions.

Xihua University (CN), State Grid Corporation of China (China) (CN), Yalong Hydro (China) (CN)
Openalex Percentile: Top 91%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.