Research on lightning intrusion wave overvoltage detection in 35KV prefabricated cabin high voltage substation

In order to reasonably plan the lightning protection measures of the substation, it is extremely necessary to accurately analyze the lightning intrusion wave overvoltage. Therefore, the research on lightning intrusion wave overvoltage detection of 35kV prefabricated high-voltage substation is proposed. After the lightning current model is constructed by using the piecewise index, the basic equivalent treatment of the substation is carried out based on the improved Euler method, the dynamic equation of the power system is solved, and the accuracy of overvoltage detection is guaranteed by controlling the time step. In the test results, the design method shows high reliability for the detection results of overvoltage peak value and waveform.

Authors

Institutions

Publication Details

Published
2025-05-07
DOI
https://doi.org/10.1117/12.3060185
Primary Topic
Advanced Decision-Making Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on lightning intrusion wave overvoltage detection in 35KV prefabricated cabin high voltage substation

Xiangsheng Lei, Shibo Dong, Xiaodong Wang, Xinghua Wang et al.
Advanced Decision-Making Techniques
article

Research on lightning intrusion wave overvoltage detection in 35KV prefabricated cabin high voltage substation

Xiangsheng Lei, Shibo Dong, Xiaodong Wang, Xinghua Wang, Yanfeng Wang
article en

Abstract

In order to reasonably plan the lightning protection measures of the substation, it is extremely necessary to accurately analyze the lightning intrusion wave overvoltage. Therefore, the research on lightning intrusion wave overvoltage detection of 35kV prefabricated high-voltage substation is proposed. After the lightning current model is constructed by using the piecewise index, the basic equivalent treatment of the substation is carried out based on the improved Euler method, the dynamic equation of the power system is solved, and the accuracy of overvoltage detection is guaranteed by controlling the time step. In the test results, the design method shows high reliability for the detection results of overvoltage peak value and waveform.

China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 87%
Advanced Decision-Making Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on lightning intrusion wave overvoltage detection in 35KV prefabricated cabin high voltage substation — Xiangsheng Lei, Shibo Dong, et al. · (2025) | TGRS Research Map | TGRS