Analysis of Adjusted Exposure Levels Based on Different Kurtosis Adjustment Algorithms and Their Performance Comparison in Evaluating Noise-Induced Hearing Loss

Evidence in this study indicated that using the kurtosis-adjusted LAeq,8hr by geometric averaging with an adjustment coefficient of 6.5 or by segmented adjustment with an adjustment coefficient of 5.4 could more accurately evaluate noise-induced hearing loss than by arithmetic averaging. The segmented adjustment provided a more flexible kurtosis adjustment scheme with a broader potential application prospect. However, the results of segmented adjustment can be severely affected by extreme values, and further research is needed to improve the accuracy and reliability of the segmented adjustment.

Authors

Institutions

Publication Details

Journal
Ear and Hearing
Published
2025-05-08
DOI
https://doi.org/10.1097/aud.0000000000001674
Citations
2
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
6.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Adjusted Exposure Levels Based on Different Kurtosis Adjustment Algorithms and Their Performance Comparison in Evaluating Noise-Induced Hearing Loss

Weijiang Hu, Jingsong Li, Meibian Zhang, Xin Sun et al.
2 citations
Ear and Hearing
Noise Effects and Management
6.24
article

Analysis of Adjusted Exposure Levels Based on Different Kurtosis Adjustment Algorithms and Their Performance Comparison in Evaluating Noise-Induced Hearing Loss

Weijiang Hu, Jingsong Li, Meibian Zhang, Xin Sun, Hengjiang Liu, Hua Zou, Wei Qiu
article en
2 citations

Abstract

Evidence in this study indicated that using the kurtosis-adjusted LAeq,8hr by geometric averaging with an adjustment coefficient of 6.5 or by segmented adjustment with an adjustment coefficient of 5.4 could more accurately evaluate noise-induced hearing loss than by arithmetic averaging. The segmented adjustment provided a more flexible kurtosis adjustment scheme with a broader potential application prospect. However, the results of segmented adjustment can be severely affected by extreme values, and further research is needed to improve the accuracy and reliability of the segmented adjustment.

Ear and HearingVol. 46(6)
Ministry of Education of the People's Republic of China (CN), Zhejiang Lab (CN), Zhejiang Center for Disease Control and Prevention (CN), National Institute for Occupational Health and Poison Control (CN)
Openalex Percentile: Top 5%
Noise Effects and Management
6.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Adjusted Exposure Levels Based on Different Kurtosis Adjustment Algorithms and Their Performance Comparison in Evaluating Noise-Induced Hearing Loss — Weijiang Hu, Jingsong Li, et al. · Ear and Hearing (2025) | TGRS Research Map | TGRS