JOIN: Optimized Light Source Activation for Deep Tissue Optical Sensing

In wearable optical sensing systems, non-idealities present during measurement affect the quality of acquired signals of interest. The issue is of particular significance in deep tissue sensing applications in which the signal of interest is faint relative to typical noise sources that contaminate the measured data. To mitigate the problem, we investigate the role of optimizing the light source activation pulse, specifically its toggling rate and duty cycle. We identify the potential for the optical source activation signal to mitigate the problem and characterize its design space. Subsequently, we present JOIN, an algorithm that yields the parameters of an optimized activation signal for a given profile of contextual noise profile. Through this algorithm, we strike a balance between avoiding noisy spectral regions associated with environmental disturbances and fitting a judiciously-selected number of signal harmonics into the measurement bandwidth, thereby enhancing the signal-to-noise ratio (SNR) of the acquired data from deep tissue by as much as 6dB. The proposed method is validated through analytical derivations, as well as test bench and in-vivo measurements on human subjects.

Authors

Institutions

Publication Details

Published
2025-05-06
DOI
https://doi.org/10.1145/3716550.3722039
Citations
1
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

JOIN: Optimized Light Source Activation for Deep Tissue Optical Sensing

Ata Vafi, Soheil Ghiasi, Kourosh Vali, Begum Kasap
1 citations
Optical Imaging and Spectroscopy Techniques
1.36
article

JOIN: Optimized Light Source Activation for Deep Tissue Optical Sensing

Ata Vafi, Soheil Ghiasi, Kourosh Vali, Begum Kasap
article en
1 citations

Abstract

In wearable optical sensing systems, non-idealities present during measurement affect the quality of acquired signals of interest. The issue is of particular significance in deep tissue sensing applications in which the signal of interest is faint relative to typical noise sources that contaminate the measured data. To mitigate the problem, we investigate the role of optimizing the light source activation pulse, specifically its toggling rate and duty cycle. We identify the potential for the optical source activation signal to mitigate the problem and characterize its design space. Subsequently, we present JOIN, an algorithm that yields the parameters of an optimized activation signal for a given profile of contextual noise profile. Through this algorithm, we strike a balance between avoiding noisy spectral regions associated with environmental disturbances and fitting a judiciously-selected number of signal harmonics into the measurement bandwidth, thereby enhancing the signal-to-noise ratio (SNR) of the acquired data from deep tissue by as much as 6dB. The proposed method is validated through analytical derivations, as well as test bench and in-vivo measurements on human subjects.

University of California, Davis (US)
National Science Foundation, National Institutes of Health
Openalex Percentile: Top 21%
Optical Imaging and Spectroscopy Techniques
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.