Flexible and Conformable Carbon Nanotube Twin Transistors for Real-Time Glucose Biosensing

Semiconductive single-walled carbon nanotube (SWNT)-based transistors have long and extensively been explored for sensing applications, biosensors in particular, but reproducible reliable results remain elusive. The random distribution of the nanotube network, as well as the variation of the network due to deformation or surrounding fluidic dynamics, leads to fluctuation of the channel current, which is difficult to control. The signal-to-noise ratio is thus low, and calibration is required. To mitigate this challenge, SWNT-based twin transistors are introduced, where one acts as a sensor and the other as a reference. The twin transistors share gate and source electrodes, and all of the source/drain electrodes are sealed by a parylene layer to minimize electrolytic leakage. A common-source amplifier circuit generates voltage signal readouts from the sensor and reference transistors, and the differential outputs reduce the noise level by 59%. Arrays of twin transistors were fabricated in a hybrid process involving photolithography, solution-based deposition of the SWNTs, and transfer to a polyurethane substrate. To demonstrate glucose biosensing, glucose oxidase was immobilized on the SWNTs in the sensor channels. A semipermeable Nafion layer was applied to embed the SWNT network. This resulted in a sensor that can deliver real-time detection of glucose in human serum and a 100% increase in normalized responses per decade of glucose concentrations between 100 μM and 100 mM. The response is proportional to the cubic root of glucose concentration, indicating that the redox electrons conducted by the nanotubes in the channel length direction contribute to the sensor response. A portable glucose-sensing system with flexible twin transistors is also demonstrated without the need for device-specific calibrations.

Authors

Institutions

Publication Details

Journal
ACS Applied Nano Materials
Published
2025-05-07
DOI
https://doi.org/10.1021/acsanm.5c01165
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible and Conformable Carbon Nanotube Twin Transistors for Real-Time Glucose Biosensing

Hanxiang Wu, Yu Song, Zhixin Xie, Qibing Pei et al.
1 links
ACS Applied Nano Materials
Neuroscience and Neural Engineering
article

Flexible and Conformable Carbon Nanotube Twin Transistors for Real-Time Glucose Biosensing

Hanxiang Wu, Yu Song, Zhixin Xie, Qibing Pei, Yuan Zhu, Hexing Yin, Meng Gao, Canran Wang, Wei Feng Gao, Ao Zhang
article en

Abstract

Semiconductive single-walled carbon nanotube (SWNT)-based transistors have long and extensively been explored for sensing applications, biosensors in particular, but reproducible reliable results remain elusive. The random distribution of the nanotube network, as well as the variation of the network due to deformation or surrounding fluidic dynamics, leads to fluctuation of the channel current, which is difficult to control. The signal-to-noise ratio is thus low, and calibration is required. To mitigate this challenge, SWNT-based twin transistors are introduced, where one acts as a sensor and the other as a reference. The twin transistors share gate and source electrodes, and all of the source/drain electrodes are sealed by a parylene layer to minimize electrolytic leakage. A common-source amplifier circuit generates voltage signal readouts from the sensor and reference transistors, and the differential outputs reduce the noise level by 59%. Arrays of twin transistors were fabricated in a hybrid process involving photolithography, solution-based deposition of the SWNTs, and transfer to a polyurethane substrate. To demonstrate glucose biosensing, glucose oxidase was immobilized on the SWNTs in the sensor channels. A semipermeable Nafion layer was applied to embed the SWNT network. This resulted in a sensor that can deliver real-time detection of glucose in human serum and a 100% increase in normalized responses per decade of glucose concentrations between 100 μM and 100 mM. The response is proportional to the cubic root of glucose concentration, indicating that the redox electrons conducted by the nanotubes in the channel length direction contribute to the sensor response. A portable glucose-sensing system with flexible twin transistors is also demonstrated without the need for device-specific calibrations.

ACS Applied Nano MaterialsVol. 8(19)
California Institute of Technology (US), University of California System (US), Samueli Institute (US)
National Science Foundation, National Eye Institute
Openalex Percentile: Top 89%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.