Study on the optimization of an ambient dose detector in an accelerator-based BNCT irradiation field

Abstract Accelerator-based boron neutron capture therapy (AB-BNCT) systems that utilize various neutron production methods have been developed in recent years. As the AB-BNCT system is a novel radiation production system, accurately measuring the neutron ambient dose is crucial for evaluating its performance and ensuring its safety. In this study, we designed a neutron detector system capable of measuring the neutron ambient dose H* in a cyclotron-based epithermal neutron source irradiation field using the particle and heavy ion transport code system 3.34 Monte Carlo simulation code. This neutron detector system comprises slow and fast neutron detectors, which are sensitive to energy ranges of 10 −9 –10 −2 MeV and 10 −2 –28 MeV, respectively. The response function of this neutron detector system exhibited satisfactory agreement with the conversion coefficients h* , and the dose measurement accuracy was within 6.5%.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Applied Physics
Published
2025-05-07
DOI
https://doi.org/10.35848/1347-4065/add593
Citations
1
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the optimization of an ambient dose detector in an accelerator-based BNCT irradiation field

Naonori Hu, Shinji Kawabata, Nishiki Matsubayashi, Shunsuke Kurosawa et al.
1 citations
Japanese Journal of Applied Physics
Radiation Effects in Electronics
0.73
article

Study on the optimization of an ambient dose detector in an accelerator-based BNCT irradiation field

Naonori Hu, Shinji Kawabata, Nishiki Matsubayashi, Shunsuke Kurosawa, Mai Nojiri, Hiroki Tanaka, Akihiko Masuda, Liang Zhao, Takushi Takata
article en
1 citations

Abstract

Abstract Accelerator-based boron neutron capture therapy (AB-BNCT) systems that utilize various neutron production methods have been developed in recent years. As the AB-BNCT system is a novel radiation production system, accurately measuring the neutron ambient dose is crucial for evaluating its performance and ensuring its safety. In this study, we designed a neutron detector system capable of measuring the neutron ambient dose H* in a cyclotron-based epithermal neutron source irradiation field using the particle and heavy ion transport code system 3.34 Monte Carlo simulation code. This neutron detector system comprises slow and fast neutron detectors, which are sensitive to energy ranges of 10 −9 –10 −2 MeV and 10 −2 –28 MeV, respectively. The response function of this neutron detector system exhibited satisfactory agreement with the conversion coefficients h* , and the dose measurement accuracy was within 6.5%.

Japanese Journal of Applied PhysicsVol. 64(6)
Kansai Medical University (JP), Tohoku University (JP), Osaka Medical and Pharmaceutical University (JP), Kyoto University (JP), Kyoto Katsura Hospital (JP), National Institute of Advanced Industrial Science and Technology (JP), Osaka University of Pharmaceutical Sciences (JP), The University of Osaka (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 29%
Radiation Effects in Electronics
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.