Dosimetry study of high repetition rate 2 MeV electron beam from a continuous-wave photocathode gun

Abstract DC-SRF-II gun, a high-brightness continuous-wave photocathode gun, has greater potential in electron beam irradiation applications. This paper presents the in-vacuum and in-air irradiation dosimetry study of the high repetition rate electron beam from the DC-SRF-II gun with both Monte Carlo simulations and experiments. Especially, high-dose uniform irradiations with flexible and accurate tuning of dose rate across orders of magnitude are demonstrated. Good stability and repeatability of the doses are also shown. The ultra-wide tuning range and precise control of irradiation time and dose rate are expected to pave the way for innovative applications across a wide range of fields.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2025-05-07
DOI
https://doi.org/10.1088/1402-4896/add57a
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
3.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetry study of high repetition rate 2 MeV electron beam from a continuous-wave photocathode gun

Jianhan Sun, Hang Xu, Jianfeng Lv, Lin Lin et al.
2 citations
Physica Scripta
Advanced Radiotherapy Techniques
3.77
article

Dosimetry study of high repetition rate 2 MeV electron beam from a continuous-wave photocathode gun

Jianhan Sun, Hang Xu, Jianfeng Lv, Lin Lin, Zihao Zhang, Senlin Huang, Juntao Liu, Shang Tian
article en
2 citations

Abstract

Abstract DC-SRF-II gun, a high-brightness continuous-wave photocathode gun, has greater potential in electron beam irradiation applications. This paper presents the in-vacuum and in-air irradiation dosimetry study of the high repetition rate electron beam from the DC-SRF-II gun with both Monte Carlo simulations and experiments. Especially, high-dose uniform irradiations with flexible and accurate tuning of dose rate across orders of magnitude are demonstrated. Good stability and repeatability of the doses are also shown. The ultra-wide tuning range and precise control of irradiation time and dose rate are expected to pave the way for innovative applications across a wide range of fields.

Physica ScriptaVol. 100(6)
Peking University (CN), Laser Research Institute (CN)
Openalex Percentile: Top 8%
Advanced Radiotherapy Techniques
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.