Comparative Analysis of Screw Loosening between SynOcta and InOcta Tissue Level Abutments: An In Vitro Study

Implants are one of the common treatments in dentistry. This treatment has various complications such as inflammation around the implant, failure of the coating, and screw loosening. Several factors contribute to screw loosening, including abutment type and collar height. Therefore, this study aims to compare the amount of loosening in two types of abutments-InOcta and SynOcta abutments.In this laboratory study, 20 titanium fixtures of the Dentis brand were divided into two groups. Each group consisted of 10 fixtures. The fixtures were mounted vertically in acrylic blocks with dimensions of 20 × 6 × 10 mm. After installing the SynOcta and InOcta abutments, the screws were torqued to 30 N·cm and re-torqued after 10 minutes. Subsequently, the samples were transferred to a chewing simulator. A compressive force of 90 N was applied for 10,000 cycles at a frequency of 75 rpm. After loading, the torque required to loosen the screws was measured, and the loosening torque was calculated. The data were analyzed using an independent <i>t</i>-test, and a significance level (<i>p</i>-value) of less than 0.05 was considered.The mean de-torque for the tissue level InOcta abutments was calculated to be 25.75 N.cm, while the mean de-torque for the SynOcta abutments was 21.98 N.cm. A comparison using the <i>t</i>-test showed that the mean de-torque for the InOcta abutment group was significantly higher than the SynOcta group (<i>p</i> < 0.001).The final results of the experiments indicate that under laboratory conditions, the de-torque of the abutment screw in the tissue level SynOcta group is significantly lower than that in the InOcta group (<i>p</i> < 0.001).

Authors

Institutions

Publication Details

Journal
European Journal of Dentistry
Published
2025-05-07
DOI
https://doi.org/10.1055/s-0045-1808257
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Screw Loosening between SynOcta and InOcta Tissue Level Abutments: An In Vitro Study

Ramin Atash, Ramin Mosharraf, Amirhossein Fathi, Sepideh Salehi et al.
4 links
European Journal of Dentistry
Dental Implant Techniques and Outcomes
article

Comparative Analysis of Screw Loosening between SynOcta and InOcta Tissue Level Abutments: An In Vitro Study

Ramin Atash, Ramin Mosharraf, Amirhossein Fathi, Sepideh Salehi, Erfan Esmaeilian
article en

Abstract

Implants are one of the common treatments in dentistry. This treatment has various complications such as inflammation around the implant, failure of the coating, and screw loosening. Several factors contribute to screw loosening, including abutment type and collar height. Therefore, this study aims to compare the amount of loosening in two types of abutments-InOcta and SynOcta abutments.In this laboratory study, 20 titanium fixtures of the Dentis brand were divided into two groups. Each group consisted of 10 fixtures. The fixtures were mounted vertically in acrylic blocks with dimensions of 20 × 6 × 10 mm. After installing the SynOcta and InOcta abutments, the screws were torqued to 30 N·cm and re-torqued after 10 minutes. Subsequently, the samples were transferred to a chewing simulator. A compressive force of 90 N was applied for 10,000 cycles at a frequency of 75 rpm. After loading, the torque required to loosen the screws was measured, and the loosening torque was calculated. The data were analyzed using an independent <i>t</i>-test, and a significance level (<i>p</i>-value) of less than 0.05 was considered.The mean de-torque for the tissue level InOcta abutments was calculated to be 25.75 N.cm, while the mean de-torque for the SynOcta abutments was 21.98 N.cm. A comparison using the <i>t</i>-test showed that the mean de-torque for the InOcta abutment group was significantly higher than the SynOcta group (<i>p</i> < 0.001).The final results of the experiments indicate that under laboratory conditions, the de-torque of the abutment screw in the tissue level SynOcta group is significantly lower than that in the InOcta group (<i>p</i> < 0.001).

European Journal of DentistryVol. 20(01)
Isfahan University of Medical Sciences (IR), Université Libre de Bruxelles (BE)
Openalex Percentile: Top 87%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.