Comparative Accuracy of Semiconductor Single-Photon Emission Computed Tomography (SPECT) Versus Cardiac Magnetic Resonance (CMR) for Myocardial Viability Assessment

Background Evaluating myocardial viability is critical for developing optimal strategies for ischemic cardiomyopathy. While semiconductor single-photon emission computed tomography (D-SPECT) demonstrated higher image quality than conventional Anger cameras for assessing myocardial viability, its accuracy compared to cardiac magnetic resonance (CMR) in the same patient cohort is still unknown. Methods We conducted a retrospective study on patients with known or suspected coronary artery disease who underwent D-SPECT and CMR within 100 days. Rest deficit score on D-SPECT and depth of contrast enhancement on late gadolinium enhancement (LGE) in CMR were classified and compared using a 16-segment analysis. Follow-up echocardiography was performed about a year after the initial examinations, detecting whether the optimal medical therapy (OMT) was followed by invasive therapy (coronary artery bypass grafting [CABG] or percutaneous coronary intervention [PCI]). The five-year survival rates were also compared. Results The study comprised 336 segments from 21 consecutive patients collected between January 2015 and December 2017. Using LGE as a viability criterion, a D-SPECT score of three had the highest diagnostic accuracy (area under the curve: 0.97). Follow-up echocardiography showed significant improvements in left ventricular ejection fraction in patients receiving OMT + PCI/CABG compared to OMT alone (OMT vs. OMT + PCI/CABG; 1.5% ± 3.4% vs. 7.1% ± 5.0%, p = 0.008); five-year survival rate did not significantly differ between the groups. Conclusions Deficits observed at rest on D-SPECT and LGE extent on CMR showed a strong correlation in evaluating myocardial viability, implying that D-SPECT is a viable alternative to CMR for this purpose.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-05-07
DOI
https://doi.org/10.7759/cureus.83679
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Accuracy of Semiconductor Single-Photon Emission Computed Tomography (SPECT) Versus Cardiac Magnetic Resonance (CMR) for Myocardial Viability Assessment

Satoaki Matoba, Arata Sano, Takeshi Maruo, Kazushige Kadota et al.
Cureus
Cardiac Imaging and Diagnostics
article

Comparative Accuracy of Semiconductor Single-Photon Emission Computed Tomography (SPECT) Versus Cardiac Magnetic Resonance (CMR) for Myocardial Viability Assessment

Satoaki Matoba, Arata Sano, Takeshi Maruo, Kazushige Kadota, Sachiyo Ono, Koshi Miyake, Takeshi Tada
article en

Abstract

Background Evaluating myocardial viability is critical for developing optimal strategies for ischemic cardiomyopathy. While semiconductor single-photon emission computed tomography (D-SPECT) demonstrated higher image quality than conventional Anger cameras for assessing myocardial viability, its accuracy compared to cardiac magnetic resonance (CMR) in the same patient cohort is still unknown. Methods We conducted a retrospective study on patients with known or suspected coronary artery disease who underwent D-SPECT and CMR within 100 days. Rest deficit score on D-SPECT and depth of contrast enhancement on late gadolinium enhancement (LGE) in CMR were classified and compared using a 16-segment analysis. Follow-up echocardiography was performed about a year after the initial examinations, detecting whether the optimal medical therapy (OMT) was followed by invasive therapy (coronary artery bypass grafting [CABG] or percutaneous coronary intervention [PCI]). The five-year survival rates were also compared. Results The study comprised 336 segments from 21 consecutive patients collected between January 2015 and December 2017. Using LGE as a viability criterion, a D-SPECT score of three had the highest diagnostic accuracy (area under the curve: 0.97). Follow-up echocardiography showed significant improvements in left ventricular ejection fraction in patients receiving OMT + PCI/CABG compared to OMT alone (OMT vs. OMT + PCI/CABG; 1.5% ± 3.4% vs. 7.1% ± 5.0%, p = 0.008); five-year survival rate did not significantly differ between the groups. Conclusions Deficits observed at rest on D-SPECT and LGE extent on CMR showed a strong correlation in evaluating myocardial viability, implying that D-SPECT is a viable alternative to CMR for this purpose.

CureusVol. 17(5)
Kyoto Prefectural University (JP), Kyoto Prefectural University of Medicine (JP), Kurashiki Central Hospital (JP)
Openalex Percentile: Top 85%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.