Experimental Investigation of Vortex Tube Performance: Influence of Inlet Pressure and Cold Mass Fraction on Thermal Outputs

This research examines the performance of a vortex tube with two intake nozzles at a diameter ratio of 2:1, a cold tube diameter (dc) of 0.6 cm, a cold tube length (Lc)of 1 cm, and a cone valve angle (θ) of 45°. The vortex tube has a 25 cm hot tube length (Lh) and a 1.3 cm hot tube diameter (Dh) with the length to diameter ratio (L/D) equal to 20. The study examined the impact of different entrance pressures (ranging from Pi= 1 to 3 bar) and cold mass fractions ( . ) on the temperatures of the hot (Th) and cold (Tc) streams. Results show that although decreasing the overall cooling and heating performance (COP), raising the input pressure increases the temperature differential between the cold and hot streams. These results offer information for enhancing vortex tube performance and open a window over possible industrial applications.

Authors

Institutions

Publication Details

Journal
SINAI International Scientific Journal.
Published
2025-04-29
DOI
https://doi.org/10.21608/sisj.2025.424702
Primary Topic
Ranque-Hilsch vortex tube
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Investigation of Vortex Tube Performance: Influence of Inlet Pressure and Cold Mass Fraction on Thermal Outputs

Ahmed A. Hussien, Sobieh Selim, Esmail .A. Koraim, A. A. Abdel-Hamied
SINAI International Scientific Journal.
Ranque-Hilsch vortex tube
article

Experimental Investigation of Vortex Tube Performance: Influence of Inlet Pressure and Cold Mass Fraction on Thermal Outputs

Ahmed A. Hussien, Sobieh Selim, Esmail .A. Koraim, A. A. Abdel-Hamied
article en

Abstract

This research examines the performance of a vortex tube with two intake nozzles at a diameter ratio of 2:1, a cold tube diameter (dc) of 0.6 cm, a cold tube length (Lc)of 1 cm, and a cone valve angle (θ) of 45°. The vortex tube has a 25 cm hot tube length (Lh) and a 1.3 cm hot tube diameter (Dh) with the length to diameter ratio (L/D) equal to 20. The study examined the impact of different entrance pressures (ranging from Pi= 1 to 3 bar) and cold mass fractions ( . ) on the temperatures of the hot (Th) and cold (Tc) streams. Results show that although decreasing the overall cooling and heating performance (COP), raising the input pressure increases the temperature differential between the cold and hot streams. These results offer information for enhancing vortex tube performance and open a window over possible industrial applications.

SINAI International Scientific Journal.Vol. 1(4)
Sinai University (EG), Menoufia University (EG)
Affordable and clean energy
Openalex Percentile: Top 91%
Ranque-Hilsch vortex tube
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.