The relationship between Erythrocyte Sedimentation Rate examination and Rapid Tuberculosis IgG/IgM Test

Mycobacterium tuberculosis is an acid-fast bacteria that causes pulmonary tuberculosis (TB) is an infectious disease that is a priority health problem in developing countries including Indonesia. Fast and accurate examination is very important in diagnosing tuberculosis. Tuberculosis examination has several methods that are not commonly applied, namely the Immunochromatography test (ICT) examination. This study is a non-experimental study with a survey method without intervention that is descriptive analytical. The purpose of the study was to see the relationship between the examination of the Erythrocyte Sedimentation Rate and the Rapid Tuberculosis IgG / IgM Test. The results obtained that the LED results of 8 samples were normal and 17 samples were abnormal, while the ICT test for IgG examination of all samples was negative, IgM 24 samples were negative and 1 sample was positive. The results of the Chi square statistical test obtained an α value of 0.618 so that it can be concluded that there is no relationship between the LED value and the results of the IgG and IgM tuberculosis tests.

Authors

Publication Details

Journal
Jaringan Laboratorium Medis
Published
2025-05-06
DOI
https://doi.org/10.31983/jlm.v7i1.12796
Primary Topic
Erythrocyte Function and Pathophysiology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The relationship between Erythrocyte Sedimentation Rate examination and Rapid Tuberculosis IgG/IgM Test

Widodo Widodo, Roni Afriansah, Damas Triyono
Jaringan Laboratorium Medis
Erythrocyte Function and Pathophysiology
article

The relationship between Erythrocyte Sedimentation Rate examination and Rapid Tuberculosis IgG/IgM Test

Widodo Widodo, Roni Afriansah, Damas Triyono
article en

Abstract

Mycobacterium tuberculosis is an acid-fast bacteria that causes pulmonary tuberculosis (TB) is an infectious disease that is a priority health problem in developing countries including Indonesia. Fast and accurate examination is very important in diagnosing tuberculosis. Tuberculosis examination has several methods that are not commonly applied, namely the Immunochromatography test (ICT) examination. This study is a non-experimental study with a survey method without intervention that is descriptive analytical. The purpose of the study was to see the relationship between the examination of the Erythrocyte Sedimentation Rate and the Rapid Tuberculosis IgG / IgM Test. The results obtained that the LED results of 8 samples were normal and 17 samples were abnormal, while the ICT test for IgG examination of all samples was negative, IgM 24 samples were negative and 1 sample was positive. The results of the Chi square statistical test obtained an α value of 0.618 so that it can be concluded that there is no relationship between the LED value and the results of the IgG and IgM tuberculosis tests.

Jaringan Laboratorium MedisVol. 7(1)
Openalex Percentile: Top 88%
Erythrocyte Function and Pathophysiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.