Pulse Profile Variability of PSR J1022+1001 in NANOGrav Data

Abstract Pulse profile stability is a central assumption of standard pulsar timing methods. Thus, it is important for pulsar timing array experiments such as the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) to account for any pulse profile variability present in their data sets. We show that in the NANOGrav 15 yr data set, the integrated pulse profile of PSR J1022+1001 as seen by the Arecibo radio telescope at 430, 1380, and 2030 MHz varies considerably in its shape from observation to observation. We investigate the possibility that this is due to the “ideal feed assumption” (IFA), on which NANOGrav’s routine polarization calibration procedure relies. PSR J1022+1001 is ∼90% polarized in one pulse profile component, and also has significant levels of circular polarization. Time-dependent deviations in the feed’s polarimetric response (PR) could cause mixing between the intensity I and the other Stokes parameters, leading to the observed variability. We calibrate the PR using a mixture of measurement equation modeling and measurement equation template matching techniques. The resulting profiles are no less variable than those calibrated using the IFA method, nor do they provide an improvement in the timing quality of this pulsar. We observe the pulse shape in 25 MHz bandwidths to vary consistently across the band, which cannot be explained by interstellar scintillation in combination with profile evolution with frequency. Instead, we favor phenomena intrinsic to the pulsar as the cause.

Authors

Publication Details

Journal
The Astrophysical Journal
Published
2025-05-06
DOI
https://doi.org/10.3847/1538-4357/adc255
Citations
1
Primary Topic
Pulsars and Gravitational Waves Research
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulse Profile Variability of PSR J1022+1001 in NANOGrav Data

H. Thankful Cromartie, Natasha McMann, Bradley W. Meyers, Alexander McEwen et al.
1 citations
The Astrophysical Journal
Pulsars and Gravitational Waves Research
1.15
article

Pulse Profile Variability of PSR J1022+1001 in NANOGrav Data

H. Thankful Cromartie, Natasha McMann, Bradley W. Meyers, Alexander McEwen, M. A. McLaughlin, Carl Schmiedekamp, Nihan S. Pol, N. Garver-Daniels, Timothy Dolch, E. C. Ferrara, S. M. Ransom, Akash Anumarlapudi, David J. Nice, David L. Kaplan, Anne M. Archibald, William Fiore, Gabriel E. Freedman, Michael T. Lam, Deborah C. Good, Haley M. Wahl, Abhimanyu Susobhanan, Joseph Glaser, Lankeswar Dey, Peter A. Gentile, Ryan S. Lynch, Ingrid H. Stairs, Brent J. Shapiro-Albert, Kathryn Crowter, Timothy T. Pennucci, Duncan R. Lorimer, P. T. Baker, Paul R. Brook, Ross J. Jennings, Ann Schmiedekamp, Paul B. Demorest, Jeffrey S. Hazboun, Kevin Stovall, Matthew T. Kerr, Paul S. Ray, Benetge B. P. Perera, Megan L. Jones, Zaven Arzoumanian, Jing Luo, Cherry Ng, Gabriella Agazie, Megan E. DeCesar, Joseph K. Swiggum, Emmanuel Fonseca, H. A. Radovan
article en
1 citations

Abstract

Abstract Pulse profile stability is a central assumption of standard pulsar timing methods. Thus, it is important for pulsar timing array experiments such as the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) to account for any pulse profile variability present in their data sets. We show that in the NANOGrav 15 yr data set, the integrated pulse profile of PSR J1022+1001 as seen by the Arecibo radio telescope at 430, 1380, and 2030 MHz varies considerably in its shape from observation to observation. We investigate the possibility that this is due to the “ideal feed assumption” (IFA), on which NANOGrav’s routine polarization calibration procedure relies. PSR J1022+1001 is ∼90% polarized in one pulse profile component, and also has significant levels of circular polarization. Time-dependent deviations in the feed’s polarimetric response (PR) could cause mixing between the intensity I and the other Stokes parameters, leading to the observed variability. We calibrate the PR using a mixture of measurement equation modeling and measurement equation template matching techniques. The resulting profiles are no less variable than those calibrated using the IFA method, nor do they provide an improvement in the timing quality of this pulsar. We observe the pulse shape in 25 MHz bandwidths to vary consistently across the band, which cannot be explained by interstellar scintillation in combination with profile evolution with frequency. Instead, we favor phenomena intrinsic to the pulsar as the cause.

The Astrophysical JournalVol. 984(2)
National Aeronautics and Space Administration, Gordon and Betty Moore Foundation
Openalex Percentile: Top 20%
Pulsars and Gravitational Waves Research
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.