Evaluating the corrosion resistance of different materials used in friction rock stabilisers in different underground environments
This study investigated the corrosion rates of various steel types and coatings used for friction rock stabilisers in a deep-level gold mine under diverse underground environmental conditions. Testing was conducted in situ within ramps, intake airways, and exhaust airways, and through simulated laboratory experiments. Results revealed that environmental variations significantly influence the corrosion performance of different materials and coatings. Duplex coatings, made up of galvanised steel with an organic paint layer, demonstrated the highest corrosion resistance. Zinc-based coatings provided moderate protection, while 3CR12 stainless steel and uncoated S420 carbon steel exhibited comparatively poor resistance under both aqueous and atmospheric conditions.
Authors
- T.R. Stacey (ORCID: https://orcid.org/0000-0003-3763-9193)
- T.P. Chidakwa
Institutions
- University of the Witwatersrand (ZA)
Publication Details
- Journal
- Journal of the Southern African Institute of Mining and Metallurgy
- Published
- 2025-04-23
- DOI
- https://doi.org/10.17159/2411-9717/3415/2025
- Primary Topic
- Tunneling and Rock Mechanics
- Type
- article
- Field-Weighted Citation Impact
- 0.00