Differences in Serum Blood Sugar Levels that were Directly Checked and Delayed for 1 Hour at Room Temperature using a Gel Separator Vacuum Tube

Blood sugar testing is essential for diabetes management and should be fast, accurate, and affordable. This study aims to determine the difference in blood sugar levels between immediate and delayed (1-hour) serum examinations using vacuum gel separator tubes at Prof. Dr. H. M. Anwar Makkatutu Bantaeng Hospital. An observational laboratory research with a comparative quantitative design was conducted on 23 purposively selected patients undergoing routine check-ups, without a history of diabetes mellitus. Blood samples were analyzed immediately and after a 1-hour delay at room temperature. Results showed that in immediate examinations, blood sugar levels ranged from 79 to 161 mg/dL, with a mean of 109.26 mg/dL. In delayed examinations, levels ranged from 81 to 164 mg/dL, with a mean of 111.74 mg/dL. Statistical analysis revealed a significant difference between the two groups (P < 0.05). The findings suggest that delaying blood sugar testing by 1 hour can lead to measurable changes in serum glucose levels, emphasizing the importance of timely sample processing in clinical settings.

Authors

Institutions

Publication Details

Journal
Frontiers in Sustainable Science and Technology
Published
2025-05-06
DOI
https://doi.org/10.69930/fsst.v2i1.236
Primary Topic
Hyperglycemia and glycemic control in critically ill and hospitalized patients
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Differences in Serum Blood Sugar Levels that were Directly Checked and Delayed for 1 Hour at Room Temperature using a Gel Separator Vacuum Tube

Islawati Islawati, Adam Adam, Tariska Inka Oktaviyani, Asdinar Asdinar
Frontiers in Sustainable Science and Technology
Hyperglycemia and glycemic control in critically ill and hospitalized patients
article

Differences in Serum Blood Sugar Levels that were Directly Checked and Delayed for 1 Hour at Room Temperature using a Gel Separator Vacuum Tube

Islawati Islawati, Adam Adam, Tariska Inka Oktaviyani, Asdinar Asdinar
article en

Abstract

Blood sugar testing is essential for diabetes management and should be fast, accurate, and affordable. This study aims to determine the difference in blood sugar levels between immediate and delayed (1-hour) serum examinations using vacuum gel separator tubes at Prof. Dr. H. M. Anwar Makkatutu Bantaeng Hospital. An observational laboratory research with a comparative quantitative design was conducted on 23 purposively selected patients undergoing routine check-ups, without a history of diabetes mellitus. Blood samples were analyzed immediately and after a 1-hour delay at room temperature. Results showed that in immediate examinations, blood sugar levels ranged from 79 to 161 mg/dL, with a mean of 109.26 mg/dL. In delayed examinations, levels ranged from 81 to 164 mg/dL, with a mean of 111.74 mg/dL. Statistical analysis revealed a significant difference between the two groups (P < 0.05). The findings suggest that delaying blood sugar testing by 1 hour can lead to measurable changes in serum glucose levels, emphasizing the importance of timely sample processing in clinical settings.

Frontiers in Sustainable Science and TechnologyVol. 2(1)
Museums Northumberland (US), State University of Makassar (ID)
Openalex Percentile: Top 88%
Hyperglycemia and glycemic control in critically ill and hospitalized patients
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Differences in Serum Blood Sugar Levels that were Directly Checked and Delayed for 1 Hour at Room Temperature using a Gel Separator Vacuum Tube — Islawati Islawati, Adam Adam, et al. · Frontiers in Sustainable Science and Technology (2025) | TGRS Research Map | TGRS