Biosafety and Blood Compatibility of Graphene Oxide Particles in In Vitro Experiments

Graphene oxide (GO), owing to its extraordinary application prospects in biomedicine, is attracting growing research attention. However, the biosafety and blood compatibility of GO required for its clearance for use in clinical trials remain elusive. Therefore, we studied the mutagenic properties of GO as well as its cell toxicity and blood compatibility. Prior to biological experiments, we assessed the structural organization of GO using dynamic light scattering and microscopic visualization methods. The results of both the Ames mutagenicity test performed on <i>Salmonella enterica</i> serovar Typhimurium TA98 and TA102 strains and the cytotoxicity test on noncancerous, immortalized human keratinocytes revealed no mutagenic or toxic effects of GO. Simultaneously, GO reduced the viability of the MelJuSo human melanoma cell line. A blood compatibility assay revealed that a concentration of 10 μg/mL was critical for GO biosafety, as greater concentrations induced diverse side effects. Specifically, GO disrupts erythrocytes' membranes in the dose-dependent manner. Moreover, GO at higher concentrations both inhibited the process of ADP (a physiological platelet agonist)-induced cell aggregation and affected their disaggregation process in platelet-rich plasma. However, in the blood clotting assessment, GO showed no effects on the activated partial thromboplastin time, prothrombin time, or thrombin time of the platelet-poor plasma. The obtained results clearly indicate that the relationship between the GO preparation method, its size, and concentration and biosafety must be cautiously monitored in the context of further possible biomedical applications.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-05-06
DOI
https://doi.org/10.3390/ma18092128
Primary Topic
Graphene and Nanomaterials Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biosafety and Blood Compatibility of Graphene Oxide Particles in In Vitro Experiments

Jacek Piosik, Nataliia Raksha, Uwe Ritter, Tetiana Halenova et al.
Materials
Graphene and Nanomaterials Applications
article

Biosafety and Blood Compatibility of Graphene Oxide Particles in In Vitro Experiments

Jacek Piosik, Nataliia Raksha, Uwe Ritter, Tetiana Halenova, Natalia Derewońko, Yu. І. Prylutskyy, О. Savchuk, Svitlana Prylutska, Grzegorz Gołuński, Patrycja Bełdzińska, Marcin Zakrzewski
article en

Abstract

Graphene oxide (GO), owing to its extraordinary application prospects in biomedicine, is attracting growing research attention. However, the biosafety and blood compatibility of GO required for its clearance for use in clinical trials remain elusive. Therefore, we studied the mutagenic properties of GO as well as its cell toxicity and blood compatibility. Prior to biological experiments, we assessed the structural organization of GO using dynamic light scattering and microscopic visualization methods. The results of both the Ames mutagenicity test performed on <i>Salmonella enterica</i> serovar Typhimurium TA98 and TA102 strains and the cytotoxicity test on noncancerous, immortalized human keratinocytes revealed no mutagenic or toxic effects of GO. Simultaneously, GO reduced the viability of the MelJuSo human melanoma cell line. A blood compatibility assay revealed that a concentration of 10 μg/mL was critical for GO biosafety, as greater concentrations induced diverse side effects. Specifically, GO disrupts erythrocytes' membranes in the dose-dependent manner. Moreover, GO at higher concentrations both inhibited the process of ADP (a physiological platelet agonist)-induced cell aggregation and affected their disaggregation process in platelet-rich plasma. However, in the blood clotting assessment, GO showed no effects on the activated partial thromboplastin time, prothrombin time, or thrombin time of the platelet-poor plasma. The obtained results clearly indicate that the relationship between the GO preparation method, its size, and concentration and biosafety must be cautiously monitored in the context of further possible biomedical applications.

MaterialsVol. 18(9)
Technische Universität Ilmenau (DE), Taras Shevchenko National University of Kyiv (UA), National University of Life and Environmental Sciences of Ukraine (UA), University of Gdańsk (PL)
Openalex Percentile: Top 91%
Graphene and Nanomaterials Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.