Single and Bi‐Layer Glass‐Based Phantoms: Robust Materials for a Calibration Standard for Fluorescence Imaging Systems

Fluorescence‐guided surgery is an increasingly common technique in neurosurgery, where 5‐aminolevulinic acid induces fluorescence in high‐grade gliomas, aiding in tumor resection and improving surgical outcomes. Reliable detection of malignant tissue fluorescence depends critically upon the clinical imaging system. Factors such as nonuniform excitation light and the presence of non‐fluorescent tissue layers over the tumor can reduce sensitivity. Characterizing imaging system performance in these scenarios is important to ensure clinical reliability. However, there are a lack of practical calibration standards available for this purpose. This study proposes a novel calibration standard to assist in characterizing a clinical fluorescence imaging system. The calibration standard uses multiple glass‐based phantoms fabricated to mimic the optical properties of tissue. Silver nanoparticles mimic the absorption spectrum of hemoglobin; small air‐filled cavities and crystals in the glass generate controlled levels of scattering; and samarium ions provide fluorescence to mimic malignant tissue. Single‐layer and bilayer glass phantoms enable assessment of fluorescence across the field of view, including characterization of the sensitivity to detect fluorescence through layers of non‐fluorescent glass, mimicking non‐malignant tissue. The glass‐based phantoms demonstrate excellent photo‐stability, homogeneity, and long‐term shelf‐life. Utility of this calibration standard is demonstrated with a commercial surgical fluorescence imaging system.

Authors

Institutions

Publication Details

Journal
Advanced Photonics Research
Published
2025-05-06
DOI
https://doi.org/10.1002/adpr.202400209
Primary Topic
Nanoplatforms for cancer theranostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single and Bi‐Layer Glass‐Based Phantoms: Robust Materials for a Calibration Standard for Fluorescence Imaging Systems

YunLe Wei, Robert A. McLaughlin, Adam J. Wells, Philipp Reineck et al.
Advanced Photonics Research
Nanoplatforms for cancer theranostics
article

Single and Bi‐Layer Glass‐Based Phantoms: Robust Materials for a Calibration Standard for Fluorescence Imaging Systems

YunLe Wei, Robert A. McLaughlin, Adam J. Wells, Philipp Reineck, Heike Ebendorff‐Heidepriem, Jiawen Li, Mingze Yang
article en

Abstract

Fluorescence‐guided surgery is an increasingly common technique in neurosurgery, where 5‐aminolevulinic acid induces fluorescence in high‐grade gliomas, aiding in tumor resection and improving surgical outcomes. Reliable detection of malignant tissue fluorescence depends critically upon the clinical imaging system. Factors such as nonuniform excitation light and the presence of non‐fluorescent tissue layers over the tumor can reduce sensitivity. Characterizing imaging system performance in these scenarios is important to ensure clinical reliability. However, there are a lack of practical calibration standards available for this purpose. This study proposes a novel calibration standard to assist in characterizing a clinical fluorescence imaging system. The calibration standard uses multiple glass‐based phantoms fabricated to mimic the optical properties of tissue. Silver nanoparticles mimic the absorption spectrum of hemoglobin; small air‐filled cavities and crystals in the glass generate controlled levels of scattering; and samarium ions provide fluorescence to mimic malignant tissue. Single‐layer and bilayer glass phantoms enable assessment of fluorescence across the field of view, including characterization of the sensitivity to detect fluorescence through layers of non‐fluorescent glass, mimicking non‐malignant tissue. The glass‐based phantoms demonstrate excellent photo‐stability, homogeneity, and long‐term shelf‐life. Utility of this calibration standard is demonstrated with a commercial surgical fluorescence imaging system.

Advanced Photonics ResearchVol. 6(8)
Royal Adelaide Hospital (AU), The University of Western Australia (AU), The University of Adelaide (AU), RMIT University (AU)
Australian National Fabrication Facility, National Heart Foundation of Australia, RMIT University, Royal Adelaide Hospital, Medical Research Council, Australian Research Council, National Health and Medical Research Council
Openalex Percentile: Top 91%
Nanoplatforms for cancer theranostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.