Design modeling and kinematics analysis of planar-based linear contact-type adaptive center-alignment device

Center alignment devices play a crucial role in industrial manufacturing and assembly, but they have certain drawbacks, including instability, complexity, and high production costs. To address these issues, this study introduces an alternative planar-based linear contact-type adaptive center-alignment device (Linear Contact Adaptive Centering Device, LCACD) that can achieve center alignment for a specific range of shaft diameters. The LCACD is based on an enhanced six-bar mechanism and features a unique rhombus-like structure that generates equivalent forces from each clamping point. To evaluate the performance and effectiveness of the proposed design, this study conducted a comprehensive analysis of the LCACD. First, the LCACD underwent kinematic analysis, where the displacement, velocity, and acceleration of the clamping point were calculated and analyzed to determine its linear range. Then, the adaptability and stability of the LCACD was validated from simulations and clamping experiments. The experimental results show that the LCACD can precisely position shaft-like components within 25%–40% of the total stroke, at a clamping error <1%. Both theoretical and empirical evidence suggests that the LCACD can attain a high degree of adaptability and precision with the use of a simplified control mechanism.

Authors

Institutions

Publication Details

Journal
Advances in Mechanical Engineering
Published
2025-05-01
DOI
https://doi.org/10.1177/16878132251335552
Primary Topic
Robotic Mechanisms and Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design modeling and kinematics analysis of planar-based linear contact-type adaptive center-alignment device

Yongmin Zhang, Zhuosheng Lü, Karl Peter Davidson, Huang Bin et al.
Advances in Mechanical Engineering
Robotic Mechanisms and Dynamics
article

Design modeling and kinematics analysis of planar-based linear contact-type adaptive center-alignment device

Yongmin Zhang, Zhuosheng Lü, Karl Peter Davidson, Huang Bin, Tony Shay, Yixin Zhou, Han QiLi
article en

Abstract

Center alignment devices play a crucial role in industrial manufacturing and assembly, but they have certain drawbacks, including instability, complexity, and high production costs. To address these issues, this study introduces an alternative planar-based linear contact-type adaptive center-alignment device (Linear Contact Adaptive Centering Device, LCACD) that can achieve center alignment for a specific range of shaft diameters. The LCACD is based on an enhanced six-bar mechanism and features a unique rhombus-like structure that generates equivalent forces from each clamping point. To evaluate the performance and effectiveness of the proposed design, this study conducted a comprehensive analysis of the LCACD. First, the LCACD underwent kinematic analysis, where the displacement, velocity, and acceleration of the clamping point were calculated and analyzed to determine its linear range. Then, the adaptability and stability of the LCACD was validated from simulations and clamping experiments. The experimental results show that the LCACD can precisely position shaft-like components within 25%–40% of the total stroke, at a clamping error <1%. Both theoretical and empirical evidence suggests that the LCACD can attain a high degree of adaptability and precision with the use of a simplified control mechanism.

Advances in Mechanical EngineeringVol. 17(5)
Eastern Michigan University (US), Foshan University (CN), Curtin University (AU)
Openalex Percentile: Top 90%
Robotic Mechanisms and Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design modeling and kinematics analysis of planar-based linear contact-type adaptive center-alignment device — Yongmin Zhang, Zhuosheng Lü, et al. · Advances in Mechanical Engineering (2025) | TGRS Research Map | TGRS